SETWORKS OPERATION (Optional Equipment)
Start-up Settings of the Controller
3
3-4
SW-07doc031016
SETWORKS OPERATION (Optional
2. Auto-calibration
This function should also be used in case of: replacement of the screw of blades width setting
system, the motor or after lubrication of the screws and other moving elements of the heads or when
significant cutting variances are observed;
Turn the main switch to the ON position.
Turn the key switch to
position and wait until ”TBS-01” disappears.
Set the head width to 80 mm using
buttons.
Press and hold down
. After a while - ”
Auto CALL
” will appear on the displays.
The controller is now ready for auto-calibration.
See Pic. 3-3.
Press
again, the controller successively performs several movements of the heads.
After performing the last movement, measure and enter the real head width using the keypad.
PIC. 3-3
AUTO
CAL.
TBS 01 Setworks
Real Size (mm)
Check real size
AUTO
CAL.
SAVE
SET
ABCDE
Position Size (mm)
ENTER
A
B
C
D
E
SET
REAL SIZE
AUTO
CAL.
Содержание TVS-FT Series