OPERATION
TVS Setup
2
2-5
MHdoc031016
Operation
2.3
TVS Setup
IMPORTANT!
Before starting to use the machine you have
to meet the following conditions:
Set up the machine on firm and level ground. Secure the saw to the ground to
prevent moving during operation. A concrete foundation or pads and anchored
bolts are recommended.
The machine can be operated with the sawdust collection system only.
The machine can be operated under roof only.
The machine can be operated in temperature range from -15
o
C to 40
o
C
(5
o
F to 104
o
F) only.
The illumination at the operator's position should be at least 300lx
1
.
The machine operator’s position is shown below.
Have a qualified electrician install the power supply (according to EN 60204
Standard). The power supply must meet the specifications given in the table
below.
1. The light source can not cause stroboscopic effect.
3-Phase
Volts
Fuse
Disconnect
Suggested Wire Size
400 VAC
40 Amps
4 mm
2
/ 11 AWG, up to
15 m/ 49 ft long
TABLE 2-0
!
Operator’s