Page 70
Troubleshooting
Integrated Modules
Integrated Modules
4-9
#826498 - Revision B - December, 2016
Cooking Zone Specific Errors - CE152TF/S, CI152TF/S, and TM15TF/S
Code
Description
Test
Action
E2 -
CI and
TM
E4 -
CI and
TM
E5 -
CE152TF/S
E6
E7
E8
E9 -
CI and
TM
EA
Coil temperature too high
Configuration implausible
(control board issue)
Relay error
Power supply error
Unspecified error
(usually accompanied by
another error)
Fan error
Temperature monitoring error
Controller error
Coil temperature test
None
None
1. Test L1 to Ground
2. Test L2 to Ground
3. Test L1 to L2
4. Test module cabinet to
adjacent ground receptacle
None
Test fan - See page 4-8
None
None
1. Test fan operation.
2. Ensure fan vent is not blocked.
3. Replace coil assembly.
1. Cycle unit power.
2. Perform unit reconfiguration.
3. Replace control board.
1. Cycle unit power
2. Replace power board.
1. L1 to Ground and L2 to Ground
between 90 VAC and 132 VAC.
2. L1 to L2 between 180 VAC and
265 VAC.
3. Neutral to Ground, Trace voltage
only.
4. Resistance to ground should be
close to zero ohms.
5. Report electrical issue to
consumer.
1. Cycle unit power.
2. Perform unit reconfiguration on
CI
and
TM
.
1. Test fan operation.
2. Ensure fan vent is not blocked.
3. Replace power board -
CE
4. Replace generator -
CI and
TM.
1. Cycle unit power.
2. Perform unit reconfiguration
3. Replace generator.
1. Cycle unit power.
2. Perform unit reconfiguration -
CI and TM
3. Replace control board.