Page 17
Electronics and Gas Theory
Integrated Modules
Integrated Modules
2-7
#826498 - Revision B - December, 2016
Wake-Up Mode - All Models
Entering Wake-Up Mode
Touch
ON/OFF
pad on any inactive control zone.
1.
All LEDs for that control zone flash until a power level is set.
•
A valid key press must be made within 10 seconds or control zone returns to Idle Mode.
•
Valid key presses in Wake-Up Mode
SIM, LO
or
MLT
– Activates the control zone at power level 1.
1.
HI
– Activates the control zone at power level 10.
2.
BOOST - CI152TF/S
- Activates the control zone at power level Boost.
3.
“…”
– Activates the control zone at a power level 2 through 9.
4.
ON/OFF
– Touch any other control zone ON/OFF pad causes that control zone to enter Wake-Up Mode.
5.
ON/OFF
– Retouch of same ON/OFF pad causes control zone to return to Idle Mode.
6.
ALL OFF
– Causes all active control zones to return to Idle Mode.
7.
CI152TF/S: Notes and Restrictions in Wake-Up Mode
If a valid key press is made but no pan is sensed on the coil assembly in 30 seconds the control zone
•
returns to Idle Mode.
During the 30 second wait, the
“...”
LEDs for that control zone flash the power level selected.
•
If a bridge is activated and a pan is detected on one control zone but not all control zones being bridged the
•
“...”
LEDs for the unsensed control zones flash the power level that has been selected.
If after 2 minutes one or more of the control zones in the bridge still does not sense a pot, all control zones
•
in the bridge return to Idle Mode, including the sensed control zone.
Display states in Wake-Up Mode
All displays for a given control zone are flashing on/off.
•
ALL OFF
display is turned on.
•
All other displays are off.
•
Operational Mode
When any control zone is active at any power level greater than 0.
Entering Operational Mode from Wake-Up Mode - All Models
SIM/MLT/LO
– Activates the control zone at power level 1.
1.
HI
– Activates the control zone at power level 10.
2.
BOOST - CI152TF/S
- Activates the control zone at power level Boost.
3.
“…”
– Activates the control zone at power level 2 through 9. Corresponding to the
“.”
which was pressed.
4.
Exiting Operational Mode
ON/OFF
– Touch the same
ON/OFF
pad returns control zone to Idle Mode.
•
ALL OFF
– All active control zones return to Idle Mode.
•