Page 64
Troubleshooting
Integrated Modules
Integrated Modules
4-3
#826498 - Revision B - December, 2016
Diagnostic Mode Procedures - All Models
a.
LED Test
All LED indicators for all control zones are on.
•
CE152TF/S
and
CI152TF/S
: front control zone
SIM/MLT
,
“…”
or
HI
pads cycles LEDs to on, dim, or
•
off.
SM15TF/S
,
FM15TF/S
and
GM15TF/S
: front control zone
LO
or
HI
pads cycles LEDs to on or off.
•
TM15TF/S
: rear control zone
LO
,
“…”
or
HI
pads cycles LEDs to on, dim, or off.
•
CE152TF/S
and
CI152TF/S
: one
“.”
displayed on the rear control zone indicates LED test is run-
•
ning.
SM15TF/S
,
FM15TF/S
and
GM15TF/S
: one
“.”
displayed on the rear control zone indicates LED
•
test is running.
TM15TF/S
: one
“.”
displayed on the front control zone indicates LED test is running.
•
“+”
pad advances to Unit Reconfiguration.
1
SM15TF/S, FM15TF/S and GM15TF/S - “-”
returns to Software Version indication.
2
b.
Unit Reconfiguration and Unit Derating - CE152TF/S, CI152TF/S and TM15TF/S
CE152TF/S
- This mode is present but shows 00 as it is not active.
•
Unit Reconfiguration CI152TF/S and TM15TF/S - software version below version V.10:
•
Touch
“+”
pad during the LED test.
1
Two
“.”
are displayed on rear control zone.
2
CF
is displayed in the 2-digit display.
3
Only one
“.”
is displayed in the front control zone.
4
Press and hold
“+”
and
“-”
pads together for 3 seconds activates the unit reconfiguration.
5
Acceptance beep is sounded after the requisite press-and-hold and the cooktop resets.
6
“-”
pad engages LED Test.
7
“+”
pad engages Control Temperature Readout.
8
Fully Rated to Derate and Unit Reconfiguration CI152TF/S and TM15TF/S - software version
•
above version V.10:
Touch
“+”
pad during the LED test.
1
Two
“.”
are displayed on rear control zone.
2
CF
is displayed in the 2-digit display.
3
Front control zone
SIM/MLT/LO
, or
HI
pads cycles between “fully rated,” or “derated” mode.
4
If first
“.”
is brighter then the second
“.”
on the front control zone, unit is in “fully rated” mode.
5
If second
“.”
is brighter then the first
“.”
on the front control zone, unit is in “derated” mode.
6
Press and hold
“+”
and
“-”
pads together for 3 seconds activates the unit reconfiguration, and sets
7
the unit in the “fully rated” or “derated” mode.
Acceptance beep is sounded after the requisite press-and-hold and the unit resets.
8
“-”
pad engages LED Test and
“+”
pad engages Control Temperature Readout.
9
NOTES on Unit Reconfiguration and Unit Derating:
Reconfiguring the unit resets the communication between the generator and control board software.
•
Reconfiguring the unit is recommended to be performed for any electronic communications error and after
replacing a generator or control board.
Derating the unit reduces the total amp draw of the unit during the highest demands.
•
The power rating of the unit does not have to be changed to perform unit reconfiguration.
•
The rear
“.”
remains at two and CF is displayed in the 2-digit display during unit reconfiguration.
•
After replacing a generator the
LOCK
light does not illuminate. The unit is locked.
•