Page 14
Integrated Modules
Integrated Modules
Electronics and Gas Theory
2-4
#826498 - Revision B - December, 2016
Timer
General Information - All Models
Available in any mode except Lock Mode, Sabbath mode, User Option mode, and Diagnostic mode.
•
The 2-digit display is blank unless there is a fault, in Diagnostic mode, or in Showroom mode.
•
Shows minutes until the timer reaches 1 minute.
•
Switches to seconds at 1 minute, and counts down from 60 seconds.
•
Timer is paused until 3 seconds after the last change in value then countdown begins.
•
Adjusting the time on a running timer resets the seconds to zero.
•
If counting down seconds and the
“-”
pad is touched the timer stops without alarm.
•
Maximum time allowed is 99 minutes.
•
Minimum time allowed is 1 minute.
•
Timer turns off after 10 seconds if no time is entered.
•
Starting the Timer - All Models
1.
Unlock the unit.
2.
Press and release the
TIMER
pad.
3.
Time increases and decreases with a touch of the
“+”
or
“-”
pad.
If the
“+”
or
“-”
pad is held continuously for 3 intervals the count rate increases.
•
If the
“+”
or
“-”
pad is held continuously for additional 3 intervals, the count rate increases again.
•
A continuously held
“+”
or
“-”
increases in this manner: 00, 01, 02, 03, 04, 05, 10, 15, 20, 30, 40, 50,
•
60, 70, 80, 90, 99.
Ending the Timer - All Models
Touch of the
TIMER
or
“-”
pad stops Timer Complete beep and clears the display.
1.
At 60 seconds the One Minute Remaining beep sounds.
•
At 00 the Timer Complete beep sounds until acknowledged.
•
Touch of the
“+”
pad adds time to the timer as described above.
2.
Display States of the Timer - All Models
When active the 2-digit display and Timer are on.
•
Other displays are as described in Idle Mode or Operational Mode.
•
Fan
Fan - CE152TF/S
Fan control is determined by the temperature on the heat sink.
•
After element assemblies are off fan continues to run until heat sink temperature is below 113° F, or up to
•
600 seconds.
Fan is limited to low speed when the element assemblies are off.
•
Temperature thresholds:
•
113° F – start low speed
•
131° F – start high speed