Integrated Modules
Integrated Modules
Electronics and Gas Theory
2-8
#826498 - Revision B - December, 2016
Valid Key Presses in Operational Mode
SIM/MLT/LO
– Activates the control zone at power level 1.
1.
HI
– Activates the control zone at power level 10.
2.
ZONE 2 - CE152TF/S
- Immediately activates the
Zone 2
element at the power level of
Zone 1
.
3.
BOOST - CI152TF/S
- Activates the control zone at power level Boost.
4.
“…”
– Activates the control zone at a power level 2 through 9.
5.
ON/OFF
– Retouch of same
ON/OFF
pad causes control zone to return to Idle Mode.
6.
ALL OFF
– All active control zones return to Idle Mode.
7.
“+” and “-” Temperature - SM15TF/S and FM15TF/S
- Three digit temperature display changes by one
8.
degree with a touch of the
“+”
or
“-”
pad.
If the
“+”
or
“-”
pad is held for more than three .5 second intervals and the count is divisible by 5, the
1.
display will increase or decrease at a rate of 5 counts every .5 seconds.
If the
“+”
or
“-”
pad is held for another three .5 second intervals and the count is divisible by 10, the dis-
2.
play will increase or decrease at a rate of 10 counts every .5 seconds.
Example: 120, 121, 122, 123, 124, 125, 130, 135, 140, 150, 160...
3.
“...”
power level display will update to show the nearest power level when the temperature is adjusted
4.
using the
“+”
or
“-”
pad.
BRIDGE - TM15TF/S
- activates the adjacent coil at the current power level.
9.
If both coils are active and
BRIDGE
pad is touched, the power level is set to the lower of the two active
•
zones.
Display States in Operational Mode
ALL OFF
is turned on.
•
SIM/MLT/LO
,
“…”
,
HI
,
ZONE 2, BRIDGE
and
BOOST
are on if they have been activated.
•
All other displays for the active control zone are off.
•
All other displays in Idle Mode are off.
•
Power level indicators (
SIM/MLT/LO
and
“…”
) less than the power level selected are on.
•
Power levels greater than selected power level are off.
•
SM15TF/S
and
FM15TF/S
: temperature display is on.
•
Coil Assembly Operational Mode and Boost Mode Notes - CI152TF/S
If two coil assemblies are powered by the same generator board and the power demand between front and
•
rear coil assembly is greater than 3700 Watts, the power level of both coil assemblies are reduced an equal
percentage to 3700 Watts combined output.
During Boost coil assemblies on the same generator board have their power level adjusted.
•
If Boost is activated, a second touch of the
BOOST
pad deactivates Boost, returning the power level to HI.
•
Boost has an operational time limit of 30 minutes.
•
Boost on CI152TF/S raise 2300 Watts coil assembly to 3150 Watts. Maximum power level on 1400 Watt
•
coil assembly is approximately 50%, or 700 Watts.
Temperature regulation - SM15TF/S
During preheat, the element power level will be set to 100% until the set point is reached.
•
Temperature regulation - FM15TF/S
A temperature off set is applied to Main RTD that will gradually increase as the liquid temperature increases,
•
so that at the maximum set-point, the maximum offset will be applied.
The maximum offset will be defined by the RTD offset configuration parameter.
•