Page 34
Integrated Modules
Integrated Modules
Component Removal
3-2
#826498 - Revision B - December, 2016
COMPONENT REMOVAL
This section explains how to remove components from the Wolf Integrated Modules. Depending on which compo-
nent you are going to remove, you may have to remove other components first. Refer to the appropriate section in
this manual that explains how to remove those various components. When reassembling, reverse the steps that
were used to remove the components.
NOTE:
Before attempting to access or remove any components from a Wolf appliance, take note of the WARN-
INGS and CAUTIONS below.
Use care when handling sheet metal parts. They may have sharp edges.
Tools Needed
6-Lobe Torx type driver size T-15
•
6-Lobe Torx type driver size T-20
•
6-Lobe Torx type driver size T-25
•
1/4” nut driver or socket
•
1/4” box wrench
•
9/32” nut driver or socket
•
5/16” open ended wrench
•
11/32” nut driver or socket
•
7/16” open ended wrench
•
1/2” open ended wrench
•
5/8” open ended wrench
•
7/8” open ended wrench
•
12 mm open ended wrench
•
18 mm open ended wrench
•
Phillips screw driver
•
Small Phillips screw driver
•
Small flat blade screw driver
•
Needle nose pliers
•
208/240 VAC APPLIANCE MUST BE PROPERLY GROUNDED AT ALL TIMES WHEN ELECTRICAL
•
POWER IS APPLIED.
•
DO NOT GROUND 208/240 VAC APPLIANCE WITH NEUTRAL (WHITE) HOUSE SUPPLY WIRE. A SEPA-
•
RATE GROUND WIRE MUST BE UTILIZED.
•
IF ALUMINUM HOUSE SUPPLY WIRING IS UTILIZED, SPLICE APPLIANCE COPPER WIRE TO ALU-
•
MINUM HOUSE WIRING USING SPECIAL CONNECTORS DESIGNED AND CERTIFIED FOR JOINING
COPPER AND ALUMINUM. FOLLOW THE CONNECTOR MANUFACTURES RECOMMENDED PROCE-
DURE CAREFULLY. IMPROPER CONNECTION CAN RESULT IN A FIRE HAZARD.
TO AVOID ELECTRICAL SHOCK, POWER TO UNIT MUST BE DISCONNECTED WHENEVER ACCESSING
•
AND/OR REMOVING COMPONENTS POWERED BY ELECTRICITY OR COMPONENTS NEAR OTHER
ELECTRICAL COMPONENTS.
TO AVOID SERIOUS BURNS AND/OR EXPLOSIONS, KEEP COMBUSTIBLES AWAY FROM APPLIANCE
•
WHENEVER A FLAME IS PRESENT. SURFACES AND COMPONENTS GET HOT DURING THE USE OF
THE APPLIANCE.
TO AVOID POSSIBLE GAS LEAKS AND/OR EXPLOSIONS, GAS TO UNIT MUST BE SHUT OFF AT SUP-
•
PLY SOURCE WHENEVER ACCESSING AND/OR REMOVING COMPONENTS.