Tab 5-1
iELBA - control cabinet
Item
Function
Effect
A9
Drive Power Consumption indica-
tion
Shows the electric motor current (in Ampere)
S7
Manual Start button
Starts the iELBA (in manual mode)
S8
Manual Stop button
Stops the iELBA (in manual mode)
H11
Power 24V indicator light
Shows if electric power is on
S5/H5
Error reset button
Shows and resets iELBA errors, refer to
NOTE:
If an error occurs, the indicator light shows the related
number of flashes.
NOTE:
Only reset an error after you have done the related
procedures.
S6
Mode Auto / Manual switch
Changes between automatic and manual mode
H3
Swing / Run indicator light
Shows the state of the running iELBA:
•
Lamp blinks - iELBA is in swing state
•
Lamp is steady - iELBA is in run state
H4
Synch OK indicator light
Shows the synchronisation state of the iELBA:
•
Lamp is steady - iELBA is synchronised to the engine
•
Lamp blinks slowly - iELBA is +/-15° from engine syn-
chronisation
•
Lamp blinks quickly - iELBA is +/-30° from engine syn-
chronisation
S1
Emergency stop button
Stops the iELBA immediately
S2/H2
Emerg. Stop Reset button
Resets an emergency stop to enable iELBA restart
The integrated indicator light shows as follows:
•
Lamp is on - an emergency stop is active
•
Lamp is off - usual operation
A10
Hour indication
Shows the running hours of the electric motor
NOTE:
A10 is installed in the control cabinet.
X72-B
AA00-7752-00AAA-043A-A
Operation Manual
Integrated electrical balancer (iELBA)
Winterthur Gas & Diesel Ltd.
- 216 -
Issue 003 2021-12
Содержание X72-B
Страница 8: ...X72 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 8 Issue 003 2021 12...
Страница 18: ...X72 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 18 Issue 003 2021 12...
Страница 137: ...X72 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 137 Issue 003 2021 12...
Страница 301: ...7 Installation 7 1 Installation 302 X72 B Operation Manual Winterthur Gas Diesel Ltd 301 Issue 003 2021 12...