Fig 6-22
MCP page - Injection - ICU Venting
001
Tab 6-13
MCP page - Injection - ICU Venting
Item
Function
Effect
001
ICU venting
To start the ICU venting:
•
The engine must be in ready to start (KM) or stop state to
start the ICU venting
•
Rail pressure must be between 150 bar -350 bar (default
value)
To rise the fuel rail pressure execute an air run
Indications:
•
Inactive
•
Waiting for air run
•
Waiting for correct fuel pressure
•
During the fuel injection venting
the fuel injection venting state will switch between Manual trigger
OFF and Manual trigger ON
To stop the ICU venting follow the below procedure:
•
Cancel ICU Venting
•
Start Engine
X72-B
AA00-4618-05AAA-043B-A
Operation Manual
MCP page - Adjust user parameters
Winterthur Gas & Diesel Ltd.
- 264 -
Issue 003 2021-12