4.13.3.2
Control box E70
The control box E70 is installed on the engine and has switches and visual indicators.
Fig 4-30
Control box E70 with option SPC
001
002
003
004
005
006
007
008
009
010
Legend
001
SCR bypass switch
006
Indication (orange) - SPC bypass
002
Indication (red) - SCR failure
007
Indication (green) - SPC running
003
Indication (orange) - SCR bypass
008
Indication (green) - SCR running
004
Indication (red) - SPC failure
009
Indication (green) - Power on
005
SPC bypass switch
010
Power switch
X72-B
AA00-9270-00AAA-043B-A
Operation Manual
LP Selective catalytic reduction system
Winterthur Gas & Diesel Ltd.
- 122 -