Fig 6-23
MCP page - Exhaust Valve Parameter
001
Tab 6-14
MCP page - Exhaust Valve Parameter
Item
Function
Effect
001
Exhaust valve button
Opens the exhaust valve user parameters
Parameters:
•
At engine stop manual EXV operation and it is necessary
to activate air spring and servo oil (run using servo oil
service pump)
•
EXV closing offset can be adjusted individually at +/- 3°
X72-B
AA00-4618-05AAA-043B-A
Operation Manual
MCP page - Adjust user parameters
Winterthur Gas & Diesel Ltd.
- 265 -