![WinGD X72-B Скачать руководство пользователя страница 486](http://html1.mh-extra.com/html/wingd/x72-b/x72-b_operation-manual_986578486.webp)
11.2.2
Signal codes - identification
An example of a signal code is shown in
Fig 11-2
Signal codes
PT 1012 C
001
002
003
004
00207
Legend
001
Function code
003
Running number
002
Function group
004
Applied system
Tab 11-3
Function code
Code
First position
Second position
A
Analysis
n/a
C
Control
Control
E
n/a
Element
F
Flow
n/a
G
Gauge
n/a
H
Hand
n/a
I
n/a
Indication
J
Power
n/a
L
Level
n/a
P
Pressure
n/a
S
Speed
Switch
T
Temperature
Transmitter
V
n/a
Valve
X
Unclassified
Unclassified
Y
Vibration
Relay
Z
Position (binary)
n/a
X72-B
AA00-0000-00AAA-030K-A
Operation Manual
List of usual values and safeguard settings - general
Winterthur Gas & Diesel Ltd.
- 486 -
Issue 003 2021-12
Содержание X72-B
Страница 8: ...X72 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 8 Issue 003 2021 12...
Страница 18: ...X72 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 18 Issue 003 2021 12...
Страница 137: ...X72 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 137 Issue 003 2021 12...
Страница 301: ...7 Installation 7 1 Installation 302 X72 B Operation Manual Winterthur Gas Diesel Ltd 301 Issue 003 2021 12...