8
For a DF engine, stop the gas system.
8.1
If you have to do maintenance downstream of the block valve (CV7285), do as
follows:
8.1.1
Make sure that the valve positions are in degassing state.
8.1.2
On the iGPR cabinet switch the button S8 to maintenance to activate the
maintenance mode.
8.1.3
On the LDU-20 iGPR page, make sure that all conditions are satisfactory.
8.1.4
On the LDU-20 iGPR page, push the Engine Inerting button to start the
engine inerting sequence.
8.1.5
Make sure that the indication in progress shows on the LDU-20.
NOTE:
The iGPR control system does the engine inerting sequence.
8.1.6
Wait until the indication passed shows on the LDU-20.
8.1.7
On the iGPR cabinet push the button S7 to degas the system.
8.2
If you have to do maintenance on a component downstream of the master shut-
off valve, do as follows:
8.2.1
Make sure that the valve positions are in degassing state.
8.2.2
On the iGPR cabinet switch the button S8 to maintenance to activate the
maintenance mode.
8.2.3
On the LDU-20 iGPR page, make sure that all conditions are satisfactory.
8.2.4
On the LDU-20 iGPR page, push the Supply Line Inerting button to start
the supply line inerting sequence.
8.2.5
Make sure that the indication in progress shows on the LDU-20.
NOTE:
The iGPR control system does the supply line inerting sequence.
8.2.6
Wait until the indication passed shows on the LDU-20.
8.2.7
On the iGPR cabinet push the button S7 to degas the system.
9
For a DF engine, stop the pilot fuel supply to the engine as follows:
9.1
Stop the pilot fuel supply from the plant.
9.2
Close the shut-off valve at engine connection 76 (pilot fuel inlet).
9.3
Release the pressure in the pilot fuel system.
9.4
Drain the pilot fuel system.
9.5
Close the shut-off valve at engine connection 77 (pilot fuel return outlet).
X72-B
AA00-0000-00AAA-151B-A
Operation Manual
Prepare the engine for standstill or for maintenance
Winterthur Gas & Diesel Ltd.
- 356 -
Issue 003 2021-12
Содержание X72-B
Страница 8: ...X72 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 8 Issue 003 2021 12...
Страница 18: ...X72 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 18 Issue 003 2021 12...
Страница 137: ...X72 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 137 Issue 003 2021 12...
Страница 301: ...7 Installation 7 1 Installation 302 X72 B Operation Manual Winterthur Gas Diesel Ltd 301 Issue 003 2021 12...