6.4
Set to ON the electrical power supply for each auxiliary blower.
6.5
Get control at the local control panel.
6.6
Start the auxiliary blowers.
6.6.1
Make sure that the auxiliary blower 1 starts immediately.
6.6.2
Make sure that the auxiliary blower 2 starts after an interval of between
3 to 6 seconds.
6.7
Make sure that the two auxiliary blowers turn in the correct direction.
6.8
Stop the auxiliary blowers.
6.9
Get control at the control panel in the engine control room (ECR).
6.10
again from the control panel in the ECR.
7
Do a check of the auxiliary blowers from the control panel in the engine control room (ECR):
7.1
On the MCM-11, disconnect terminal X33.
7.2
Start the auxiliary blowers.
7.3
Make sure that the command and feedback of auxiliary blowers continue to
operate.
NOTE:
If the auxiliary blowers do not operate, do a check of the wiring to the
starter box.
7.4
Stop the auxiliary blowers.
7.5
On the MCM-11, connect terminal X33.
7.6
On the IOM-10, disconnect terminal X11.
7.7
Start the auxiliary blowers. Command and feedback of auxiliary blowers must
continue to operate.
7.8
If the auxiliary blowers do not operate, do a check of the wiring to the starter box.
7.9
Stop the auxiliary blowers.
7.10
On the IOM-10, connect terminal X11.
7.11
Get control at the local control panel.
7.12
again from the local control panel.
8
Do a check of the turning gear interlocks:
8.1
Make sure that the turning gear is engaged.
8.2
Make sure that the pressure transmitter PT5017C and the switch ZS5016C do not
operate.
NOTE:
The pressure transmitter PT5017C operates at 2.0 bar.
8.3
Make sure that the indication Turning Gear Engaged shows on each control panel
(in the engine control room and at the local maneuvering stand).
8.4
Make sure that no starting air is in the starting air supply pipe:
8.4.1
Make sure that the starting air shut-off valve 30-4325_E0_1 is in the
position AUTO.
8.4.2
Disconnect the plugs on the two solenoid valves CV7013C and CV7014C.
8.4.3
Open the two drain valves in the starting air supply pipe.
8.5
Get control at the local control panel.
8.6
Select the button START AHD.
8.7
Make sure that the indication Turning Gear Engaged is shown on each control
panel.
8.8
Make sure that no start command is released.
8.9
again from the locations that follow:
•
Control panel in the engine control room (ECR)
X72-B
AA00-0000-00AAA-340A-A
Operation Manual
Do regular safety checks
Winterthur Gas & Diesel Ltd.
- 326 -
Issue 003 2021-12
Содержание X72-B
Страница 8: ...X72 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 8 Issue 003 2021 12...
Страница 18: ...X72 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 18 Issue 003 2021 12...
Страница 137: ...X72 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 137 Issue 003 2021 12...
Страница 301: ...7 Installation 7 1 Installation 302 X72 B Operation Manual Winterthur Gas Diesel Ltd 301 Issue 003 2021 12...