English INSTALLATION

42 

WILO SE 11-2016 V06 DIN A4

• Ensure the proper edge clearance in order to 

prevent the construction material from tearing or 
chipping.

• The depth of the borehole depends on the length 

of the bolts. The borehole should be 5 mm deeper 

than the bolt length.

• Drilling dust impairs holding strength. Therefore, 

Always blow or vacuum out the borehole.

• 

Make sure the fixation material is not damaged 

during installation.

5.3.2.  Stationary dry well installation in buildings

Work steps

The lifting unit is installed in the following steps:

• Positioning the lifting unit and anchoring it to the 

floor

• Connecting the pressure pipe
• Connecting the inlet
• Connecting the ventilation line
• 

Defining the working area

Positioning the lifting unit and anchoring it to 

the floor

Fig. 2: 

Installing the lifting unit 

1 Attachment points
2 Fastening straps

The lifting unit is anchored to the floor with four 
fixations.

1.  Place the lifting unit in the required position and 

align it.

2.  Mark out the boreholes.
3.  Move the lifting unit to one side and drill the 

boreholes according to the fixation material used.

4.  Reposition the lifting unit and fasten it to the 

fastening straps with the respective fixation 

material. 

Max. tightening torque: 

30 Nm

Connecting the pressure pipe

BEWARE of pressure surges! 

Pressure surges can exceed the maximum 

permitted operating pressure many times 

over. This can cause the pressure pipe to 

burst! Attempt to avoid pressure surges by 

the way that the pressure pipe is routed. The 

piping and connection elements used must 

have corresponding pressure resistance!

NOTE

• 

According to EN 12056-4, the flow rate at 

the duty point must be between 0.7 m/s and 

2.3 m/s.

•  Reducing the pipe diameter in the pressure pipe 

is not permitted.

The following information must be observed 

when connecting the pressure pipe:

• The pressure pipe must be self-supporting.
• The pressure pipe must be connected so it is free 

from vibration, noise-insulated and flexible.

• The connection as well as all unions must be 

absolutely leak-tight.

• The routing of the pressure pipe must be frost-

proof.

• 

To avoid any backflow from the main public sew

-

er, install the pressure pipe as a loop. The bottom 
edge of the pipe loop must be above the locally 

defined backflow level at its highest point.

• Gate valves and non-return valves are already 

built-in. The discharge pipeline can be connected 
directly.

Fig. 3: 

Connecting the pressure pipe 

1 Pressure connection with pipe connection
2

Pressure connection with flange connection

1.  The pressure pipe must be routed so that the 

connection is perpendicular to the pressure 
connection. Please refer to the system documen-
tation or the catalogue for the precise dimensions 
of the lifting unit.

2.  Connecting the pressure pipe to the pressure 

connection:

• Pipe connection 

Connect the pressure connection and the 
discharge pipe to a welded bushing. Weld the 
connection so it is leak-tight by heating the 
bushing.

• Flange connection 

Use a flange connector for flexible and acous

-

tically insulated mounting of the discharge 
pipeline to the pressure connection. Place a 

gasket between flange connector and pressure 

connection. 

Max. tightening torque: 

50 Nm

Connecting the inlet

The following information must be observed 

when connecting the inlet pipe:

• The connection is made at the supply box/dis-

tributor.

• The inlet must be routed so it is self-draining. 

Furthermore, an inlet surge must be prevented, as 
must any air intake.

An inlet surge and/or air intake can cause mal-

functions of the lifting unit!

• The connection as well as all unions must be 

absolutely leak-tight.

• The structure of the inlet must happen with a fall 

to the supply box/distributor.

• A gate valve must be installed in the inlet up-

stream of the supply box/distributor!

Fig. 4: 

Connecting the inlet 

1 Supply box/distributor 
2 Inlet connection

1.  Route the inlet up to the supply box/distributor.
2.  Place a gasket between supply box/distributor 

and inlet pipe flange.

Содержание EMUport CORE

Страница 1: ...ncionamiento no Monterings og driftsveiledning sv Monterings och sk tselanvisning fi Asennus ja k ytt ohje hr Upute za ugradnju i uporabu sr Uputstvo za ugradnju i upotrebu sl Navodila za vgradnjo in...

Страница 2: ...Fig 1 EMUport CORE A Fig 1 EMUport CORE B 1 5 3 3 3 7 7 6 2 8 8 8 9 9 10 10 1 4 4 1 5 3 3 3 7 7 6 2 8 8 8 9 9 10 10 11 11 1 4 4...

Страница 3: ...Fig 2 Fig 3 1 1 1 2 2 2 2 2 1...

Страница 4: ...Fig 6 A CORE A Motor P 13 Fig 5 Fig 4 2 1 1 5 1 2 4 3 M 3 gn ye W V 21 20 U PE 6 DK...

Страница 5: ...E A Motor P 17 5 1 2 4 3 M 3 gn ye W V 20 21 22 U PE 6 3 4 5 2 1 M 3 gn ye W1W2 V1 20 21 22 U1 V2 U2 PE 6 8 7 9 Fig 7 A CORE B Motor P 13 Fig 6 D CORE A Motor FK 17 1 5 1 2 4 3 M 3 gn ye W V 21 20 U P...

Страница 6: ...Motor P 17 Fig 7 D CORE B Motor FK 17 1 3 4 5 2 1 M 3 gn ye W1W2 V1 20 21 22 U1 V2 U2 PE 6 8 7 9 DK M 3 gn ye W V 21 20 U PE DK DK Fig 8 1 2 2 1 Fig 7 B CORE B Motor P 17 5 1 2 4 3 M 3 gn ye W V 20 2...

Страница 7: ...Fig 12 Fig 11 Fig 10 3 3 2 1 4 3 1 2 4 2 1 3 5 Fig 9 3 1 2...

Страница 8: ...Fig 13 Motor P 13 P 17 Fig 13 Motor FK 17 1 Fig 13 Motor FK 17 1 D M D...

Страница 9: ...39 3 8 Scope of delivery 39 3 9 Accessories optionally available 39 4 Transportation and storage 39 4 1 Delivery 39 4 2 Transport 39 4 3 Storage 40 4 4 Return delivery 40 5 Installation 40 5 1 Genera...

Страница 10: ...tems and or com ponents This operation and maintenance manual refers to the lifting unit indicated on the title page 1 5 Warranty In general the specifications in the current Gen eral Terms and Condit...

Страница 11: ...stallation The lifting unit must be disconnected from the electricity network and secured against reactivation All rotating parts must have come to a standstill The operator must report any faults or...

Страница 12: ...ed or if they do not work 2 5 Conduct during operation When operating the lifting unit always follow the locally applicable laws and regulations for work safety accident prevention and handling electr...

Страница 13: ...n compliant with the intended use 3 1 1 Application limits DANGER due to overpressure Exceeding the application limits can result in excessive pressure in the collection reservoir in the event of syst...

Страница 14: ...upstream of the discharge ports of the sewage pumps and filter out non permitted large solid materials This way only pre cleaned sewage passes through the idle sewage pump into the shared collection r...

Страница 15: ...ion system 20 Max inlet in m h 2 Number of pumps 10 Maximum delivery head in m at Q 0 A Version A standard version B comfort version 3 8 Scope of delivery Sewage lifting unit ready for connection with...

Страница 16: ...l result in damage to these components and the lifting unit Never immerse the electrical compo nents in a liquid and protect them against the ingress of moisture The lifting unit must be protected fro...

Страница 17: ...this will be required for installing dismantling the lifting unit The lifting equipment must be able to reach the place where the lifting unit is used and placed without danger The set down location...

Страница 18: ...he pressure pipe must be connected so it is free from vibration noise insulated and flexible The connection as well as all unions must be absolutely leak tight The routing of the pressure pipe must be...

Страница 19: ...are present in the working area during operations then a guard must be installed 5 4 Electrical connection POTENTIALLY fatal danger due to electrical voltage Incorrect electrical connections can caus...

Страница 20: ...could lead to fatal injury due to explosion The connection of the level sensor must be made using an intrinsically safe electric circuit e g Zener barrier Observe in this connection local stat utory...

Страница 21: ...cking the installation Check the installation to ensure all the necessary work was carried out properly Fastening Floor fixation carried out properly Mechanical connections All of the connections are...

Страница 22: ...unit operates in automatic mode by default and is switched on and off using the inte grated level control device 1 Switching on the system via the switchgear Main switch to ON 2 Check the switchgear s...

Страница 23: ...ances During removal there is potential for contact with fluids that represent a health hazard The following points must be observed without fail Wear appropriate full body protection as well as prote...

Страница 24: ...After maintenance or repair work the lifting unit must be put back in operation in accordance with the Commissioning chapter Note the following All maintenance and repair work must be carried out by W...

Страница 25: ...loyee and the end user NOTE We recommend concluding a maintenance contract for regular maintenance work Please contact Wilo customer service for more infor mation about this 8 4 1 Maintenance interval...

Страница 26: ...aning the solids separation reservoir 1 Sewage pump 2 Screwed connection at the discharge port of the sew age pump 3 Pump inlet including screen holder 4 Solids separation reservoir 5 Pump inlet solid...

Страница 27: ...3 Delivery head too small 1 2 3 4 5 8 11 12 13 Lifting unit runs roughly loud noise 1 2 3 9 12 13 14 9 2 Overview of possible causes and their remedies 1 Inlet or impeller clogged Remove deposits from...

Страница 28: ...V06 DIN A4 10 Appendix 10 1 Spare parts Spare parts can be ordered from Wilo customer service To avoid return queries and incorrect or ders the serial and or article number must always be supplied Sub...

Страница 29: ...Pioneering for You WILO SE Nortkirchenstra e 100 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: