Possible reason:
Check if the water valve opens and if the
valve connections are OK.
If the valve open (noise) and no water is delivered,
the water tube in the freezer door is blocked by ice.
In this case you must change the complete freezer door
with the modified water tube fixation.
On IDI appliances with R134a ice maker:
Check points at the ice maker:
Test points L + V
water valve check
Connect L + V with an insulated piece of wire (1,5 mm²).
The valve should switch on and water should flow into the mould.
Note:
If the mould heater is defective the valve will be not activated.
As indication for the modified door, the factory put a stamp on the
packaging and on the bottom side of the service door.
It shows you the production week of the service door in 2005. Service
doors without a stamp, haven’t the modification inside.
Troubleshooting & Diagnostic:
Not delivered water.