57
Bimetal check: There must be an electrical
continuity between the orange and white wires.
Thermofuse check: There must be an electrical
continuity between the brown and blue wires.
Troubleshooting & Diagnostic:
Freezer temperature too warm
Over temperature alarm always on (*)
(*) Note:
The over temperature alarm is active ONLY on appliances produced before june 2007.
Possible reason:
Gas
leakage.
Check with a leakage spray all
soldered places or measure the
pressure in the cooling cycle.
If there exist a leakage or there is not
enough cooling gas inside, make the
repair to the present valid regulations
of cooling cycles.
Possible reason:
Evaporator completely iced.
Thermofuse & bimetal
Defrost heater
Main Board
Could be the result of defect…
Check the resistance
value of the heating
element. It must be
between 84-94
Only when everything is
checked and correct
working, you have to
change the Main Board.
Check the heater
connection (with BI test
and visually).