27
Icemaker E-module - Optical diagnostic
The service diagnostics mode only checks the functionality of the optics. To enter this mode,
turn E-module (Ice-Maker) OFF by means the User Interface Ice-Maker ON/OFF push-button,
then ON again; open the freezer door and look at the diagnostic GREEN LED hidden behind
E-module (Ice-Maker) service door.
Trouble shooting chart for optics diagnostic
TEST
RESULT
POSSIBLE CAUSE
CORRECTIVE
ACTION
Dirt on optics.
Clean dirt from optics.
Frost on optics lenses.
Clean frost from lenses.
2 LED pulses, repeated.
Failed optics.
Replace emitter and
receiver boards and
retest.
1 LED pulses, repeated.
E-module (Ice maker) is
in 5 minutes “harvest”
cycle.
To verify, look at the
blades, they should
turning to reach the
home position. If not,
replace E-module (Ice-
Maker).
Incorrect wiring at E-
module (Ice-Maker),
emitter or receiver
board.
Correct wiring and re-
test.
No LED pulses.
No power to E-module
(Ice-Maker).
Replace E-module (Ice-
Maker) and re-test.
Optics
Diagnostic
Mode (optics
test only)
LED solid ON
E-module (Ice-Maker)
powered with blades at
home position and
waiting for next harvest.
Everything is OK. No
corrective actions are
necessary.
WARNING
Electrical Shock Hazard
Voltage is present during these tests.
SbS IDI R600 ELECTRONIC E-module