Diagnostics:
1.
Switch OFF the Ice-Maker using the User Board push-button.
2.
Remove the cover in order to reaching the TEST POINTS. It is not more necessary slide the ice
maker out of the mounting rails.
3.
Connect jumper test holes “T” and “H” to bypass the bimetal thermostat and start a harvest.
4.
Make sure there is the mechanical bracket ice level in rest position. Close the freezer door
and switch on the system using the User Board ON/OFF push-button.
5.
Open the freezer door and observe the ice maker. A “harvest” should be in progress, i.e.
the ice cube rake is turning.
NOTE: If holes “T” and “H” are properly bridged and the ice maker will not run, stop the test,
and check the ice maker.
6.
Remove the jumper before the fingers reach 10:00 o’clock position.
7.
Verify the mould is filling up with the water (valve activation).
8.
Test ends.
SbS NO IDI MECHANICAL
WARNING
Electrical Shock Hazard
Voltage is present during these tests.