30
Trouble shooting chart for component diagnostic
TEST
RESULT
POSSIBLE CAUSE
CORRECTIVE ACTION
Ice Maker is not
powered.
Switch ON the Ice Maker by
means the User Board and retest.
Thermal fuse in Ice
Maker harness is open.
Replace ice maker harness and
retest.
Incorrect wiring at emitter
or receiver board.
Correct wiring and retest.
No LED pulses.
Problem with Ice Maker
See "Ice Maker Checks” below.
2 LED pulses.
Optics board defective.
Replace emitter and receiver
boards and retest.
LED on steady.
Ice Maker control circuit
is functioning normally.
None required.
Ice
Maker
Control
Circuit
1 LED pulses, repeated.
Ice-Maker in harvest
mode.
Wait till the blades reach rest
position.
Thermal fuse in Ice
Maker harness is open.
Replace ice maker harness.
No power applied to Ice
Maker module.
Wiring harness problem.
Check continuity in wiring
harness.
Ejector bar does not
move.
Motor has failed.
Replace ice maker E-module.
Water valve wiring
connection problem.
Check wiring to valve.
Customer’s water supply
is problem.
Check for proper water supply.
Frozen water fill tube.
Defrost the water fill tube and
check for seeping valve.
Ice
Maker
Checks
No water fill.
Water valve has failed.
Replace water valve.
Содержание Cassinetta
Страница 8: ...8 ...
Страница 41: ...41 Inside Ice Sensor Guide Ice Full Test Switch Not Used SbS NO IDI Sankyo ice maker ...
Страница 43: ...43 TEMPERATURE VS RESISTANCE VALUE TABLE FOR SANKYO ICEMAKER ...