39
COMPONENTS DIAGNOSTIC MODE CHART
TEST
RESULT
POSSIBLE CAUSE
CORRECTIVE ACTION
Ice Maker is not
powered.
Checks poles relay output on the
Main Board.
Thermal fuse in Ice
Maker harness is open.
Replace ice maker harness.
No power applied to Ice
Maker module.
Wiring harness problem.
Check continuity in wiring
harness.
Ejector bar does not
move.
Motor has failed.
Replace ice maker module.
Thermostat jumper not
making contact.
Reposition jumper.
Heater is not on.
Heater has failed
Replace ice maker.
Thermostat jumper was
left installed past 11:00
position.
Remove jumper by 10:00 position
of ejector bar.
Water valve wiring
connection problem.
Check wiring to valve.
Customer’s water supply
is problem.
Check for proper water supply.
Frozen water fill tube.
Defrost the water fill tube and
check for seeping valve.
No water fill.
Water valve has failed.
Replace water valve.
Ice
Maker
Checks
Ejector bar does not stop
at “home” position.
Thermostat jumper not
removed.
Remove thermostat jumper.