Technical Data Summary Sheet
Fuse Ratings
Component Torque Settings (Nm)
Error Codes
F1
20A
USB Assembly
2.
1
E79
Touch screen released in <15 sec
F2
20A
Door Switches
1.
0
E80
Touch screen held for >5 sec
F3
13A (*12A)
Door Skin
2.
1
E81
Firmware updated
SRB
1.25A
Door Handle
2.
1
E82
Menu updated
Fuse Bracket
2.
1
E83
Incompatible SRB version
Overheat Thermostat settings
On/Off Switch PCB
1.
0
E84
Date not set
Cavity Stat
300
o
C
Air Filter Assembly
1.
0
E85
Not used
Mag Stat
125
o
C
Cavity to Base
2.
1
E86
Oven switched on
Fan IP
150
o
C
Cooling Fan
2.
1
E87
Touch screen held for 15 sec
Door Choke
2.
3
E88
Supply voltage out of range by
±
10%
Current Draws @ 230VAC
Door Hinges
3.
5
E89
Recommission test failure cooling fan
Heating Element
9 – 10A
Mains Filter Bracket
2.
1
E90
Recommission test failure convection fan
Magnetron
7 - 8A
Cavity Overheat Thermostat
0.
7
E91
N/A for e2s - Recommission test failure
turntable
Panels
2.
1
E92
Recommission test failure heater <1A
Circuit Breaker Ratings
Partition Plate
2.
1
E93
Recommission test failure magnetron(s) <5A
e2s 1ph 1000W
D16
Stirrers
1.
0
E94
Recommission test failure air filter
e2s 1ph 2000W
D32
Impinger Plate
1.
2
E95
Recommission test failure air filter
e2s 2ph 2000W
D16
VDF Bracket
2.
8
E96
Recommission test failure door switches
Waveguides
2.
1
E97
Recommission test failure door switches
Component Resistances
Heating Element Wiring
2.
0
E98
Incomplete cleaning cycle, no longer used
Voltage Relay Coil
255
W
Mains Filter Wiring
1.
2
E99
Filter override accepted
EMI Filter L - N
330k
W
*
Magnetron
2.
1
E100 Mains supply switched on
LV Transformer Pri 81
W
Convection Fan Motor Assembly
2.
1
E101 Magnetron(s) failed on request. <5A.
LV Transformer
Sec
1.3
W
Door Switch Bracket
2.
8
E102 Heater on without request. >1A
Cooling Fan
205
W
*
QTS to panel
0.
8
E103 Ambient Overheat. QTS or SRB >70
o
C
Stirrer Motor
7-8
W
SRB Bracket
2.
1
E104 Safety circuit open (Overheat Thermostats)
Convection Fan
9
W
±
10%
HV Transformer to Base
3.
5
E105 Supply frequency out of range by
±
2%
Heater Element
19
W
Voltage Selection Relay to Base
0.
8
E106 Cavity 25
o
C above setpoint