Merrychef eikon
®
e2s service and repair manual
28
_______________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________
3 Technical data
Back to contents >
Description
Features
Function
Rating
Trouble shooting
EMI Filters
(Mains Filters)
*Note: JP model has
three filters. Using the
standard mains filter
for F2 and a larger
mains filter, fitted
above, for F1 & F3. The
third, standard size
filter, is located to the
left of the HV
transformer for the
VFD mains supply.
Filters unwanted
frequency noise from
interfering with various
circuits and
components in the
oven
For use on the main
supply feeding all
branch circuits.
250VAC 20A @ 40
o
C
Line (L&N) or Load
(L’&N’) = 330k
Ω
L1 (L&L’) or L2 (N&N’) =
0
Ω
Ground (G&L), (G&N),
(G&L’), (G&N’) = open
*JP model (large filter)
250VAC 50/60Hz /
250VDC, 20A @40
o
C
Line (L&N) or Load
(L’&N’) = 222k
Ω
L1 (L&L’) or L2 (N&N’) =
0
Ω
Ground (G&L), (G&N),
(G&L’), (G&N’) = open
Check for signs of
overheating or dis-
colouration.
Check for shorts to
ground from all Live
and Neutral terminals.
Check for steady
voltage (Live & Neutral)
to the filter.
Check for steady
voltage (Live & Neutral)
out of the filter
ELV Transformer (Low
Voltage Transformer)
3
/
16
” spade connections
on primary winding
and
1
/
4
” spade
connections on
secondary winding
Provides a step down
voltage of 24VAC to the
Smart Relay Board for
controller operation.
This 24VAC is supplied
to the DC rectifying
circuit on the SRB
Primary Voltage
230VAC
Secondary Voltage
24VAC / 28VA @ 70
o
C.
Resistances: Primary =
81
W
, Secondary = 1.3
W
Check for opens, shorts
or grounds
Check resistance of
windings
Check SRB connections
X103, X103.1, X1 and
fuse
Check for lit LED’s on
SRB
Check primary winding
voltage
Check secondary
winding voltage.
On/Off Switch
On/Off Switch PCB
toggle
Provides a 12VDC
return to the Smart
Relay Board to activate
oven functions
Switched Voltage:
12VDC
Rating: 6A / 12V
Resistance: If open
O.L., if closed = 0
Ω
Check continuity
through switch.
Check for 12VDC
through switch.
Check for firm clicking
sound when switching
on and off.
Check SRB connection
X18a for security
Check Error Log for E86
events
Cooling Fan
*Note: JP model has a
different fan
Supplies fresh air into
the component
chamber to cool down
the electrical
components. The fan
should run counter
clockwise (looking
down from above). The
fan will continue to run
once the oven is
switched off, until the
cavity temperature
drops below 50
o
C
(“Shutting down’’
displayed).
Motor has internal
Thermal Overload
Protection on the Live
Supplies fresh air into
the component
chamber to cool down
the electrical
components. fan
should run counter
clockwise. Draws air in
through the filter
under the door and out
the rear of the oven
230VAC 0.23A 52W @
50Hz. Resistance: 190 -
210
W
(205
W
across
connection terminals).
Capacitor 1.5
µ
F
*JP Model
200VAC 50/60Hz,
0.33/0.4A, 62/67W.
Resistance: 125
W
&
167
W
(125
W
across
connection terminals).
Capacitor 3
µ
F
Check for opens, shorts
or grounds
Check for locked rotor
(Power Off)
Check SRB connection
X8
Check SRB LED
Check for Live supply
potential on fan
connection
Check Error Log for
SRB & QTS
temperatures and E103
events