Merrychef eikon
®
e2s service and repair manual
53
_______________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________
5 Service information
Back to contents >
Error
Problem
Solution
E105:
FREQUENCY
SUPPLY
Mains supply
frequency is
±
2% from
nominal
Mains supply frequency is
±
2% from nominal or interference e.g., an internal
microwave leak? Most of the issues found here are related to an unstable power
supply of the building, i.e., Generators. It is recommended to check the supply
and/or analyse the error log on a computer
Ensure there are no microwave leaks by inspecting the unit with a suitable
microwave leak detector
Ensure there is a bowl (suitable for microwaves) of water (250ml cold) and activate a
microwave leak test in the service screen mode. Check around the door seals front
and rear of the unit. If microwave leaks are observed (if a level of 5mW/cm
2
or
higher is observed the oven must not be used until repaired) unplug from the mains
and investigate. Note: there should be no microwave leakage and corrections
should be made if any leakage is detected above 0.5mW/cm
2
.
Check for damaged cavity thermocouple
Information Error Codes:
Error
Problem
Solution
E000: OK
Communications
have been
established
between the SRB
& QTS boards
Solution not required if event recorded after mains power has be supplied to the
oven (E100) or during successful firmware updates.
Check all QTS & SRNB connections.
Check condition and connections on communication cable, SRB X11 to QTS X4.
E081:
UNKNOWN
ERROR
Firmware
updated, check
sum error
Solution not required
E082: MENU
FILE UPDATE
‘Event’ not an
error. Menu or
App (.crb) files
have been
updated
Solution not required
E086: SOFT
POWER ON
‘Event’ not
necessarily an
error.
SRB received
ELV voltage
signal from the
on/off switch or
reboot during
firmware
update(s)
Solution not required if events correspond with normal operation.
Check connections and on/off switch if event is recorded multiply times in quick
succession
E098:
INCOMPLETE
CLEANING
Cool down
cleaning process
not completed
Event recording no longer in use.
Download the up to date firmware from
merrycheftechnical.com
and load on to
the oven
E100: MAINS
POWER ON
‘Event” not
necessarily an
error.
SRB supplied
with 24V from
transformer
once mains
power is
switched on.
Solution not required if events correspond with normal operation.