![Welbilt Merrychef 32Z3923 Скачать руководство пользователя страница 72](http://html1.mh-extra.com/html/welbilt/merrychef-32z3923/merrychef-32z3923_service-and-repair-manual_953836072.webp)
Merrychef eikon
®
e2s service and repair manual
72
_______________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________
6 Replacing components
Back to contents >
12.
The door choke is removed by unfastening the sixteen M8 hex nuts. On refitting
the door choke, ensure the studs are positioned correctly in the centre of the hole and
not resting on the shoulder of the stud. The nuts should be retightened diagonally in the following sequence to 2.3 Nm.
Fitting the components of the door assembly
Follow the steps in the reverse order to reassemble the components of the oven door and fit to the oven.
Refitting the door assembly
On refitting the door to the oven, check that the door seal firmly meets the cavity frame all the way around once closed. A
poor sealing door can cause issues with the oven’s operation.
To set the door to the cavity correctly:
1.
Refit the door to the oven with the insulation and door skin removed.
2.
Close the door
3.
Loosen the four M8 hex bolts holding the door hinge assemblies and push the door squarely against the cavity.
Whilst holding the door in this position, tighten the four M8 hex bolts.
4.
Remove the door from the oven and refit the insulation
and door skin.
5.
Refit the door to the oven
6.
Close the door and recheck that the door seal tightly
meets the cavity frame all the way around.
Refit the door to the oven in the reverse order to removal. Ensure
the hinges locate correctly before reinstalling the locking tabs.
Once refitted, ensure the door switch settings and operation is
correct.
6.
Turn the door assembly
around.
Slide the cover panel away
from the door handle to
remove it from the door
frame.
7.
Wearing gloves, remove
the two thermal insulation
pads located between the
springs attached to the door
hinges and the door handle.
8.
Unfasten the four M8 hex bolts (two on each side)
to detach the door handle.
9.
Wearing gloves,
remove all insulation
pads/mats from the
door.
10.
Unfasten the two M8 hex
bolts for each door hinge
assembly.
11.
Remove/replace
the door hinge
assemblies if
required.