5 Service information
Back to contents >
DANGER
High voltages and significant currents are present at the high voltage capacitor and HV Circuit.
It is very dangerous to work near this part when the oven is on.
NEVER make any electrical measurements on the high voltage circuits, including the magnetron filament, whilst the oven is
connected to the mains power supply.
High voltage magnetron test
Ensure the following requirements have been met before starting the test:
§
The appliance has been disconnected from the power supply and protective measures have been taken to ensure
the power cannot be switched on again.
§
The appliance is cool.
§
The high voltage capacitors are discharged before commencing work.
§
The casing of the appliance has been removed.
DANGER
High voltages and significant currents are present at the high voltage capacitor and HV Circuit.
It is very dangerous to work near this part when the oven is on.
NEVER make any electrical measurements on the high voltage circuits, including the magnetron filament, whilst the oven is
connected to the mains power supply.
3.
Connect the DMM to both terminals
of the high voltage capacitor.
The test is passed if the DMM display
reads approx. 10 M
Ω
.
4.
Connect the DMM to one terminal and the metal outer case
of the high voltage capacitor.
The test is passed if the DMM display reads "open circuit".
Repeat the test for the other terminal and the metal outer case.
1.
Remove all electric connections from the high voltage capacitor.
2.
Using a Digital Multi-Meter (DMM), check for continuity.
Results should be as follows:
5.
Using a megger/insulation tester, test the insulation resistance between both
terminals and the metal outer case of the high voltage capacitor.
The test is passed if the megger/insulation tester display reads over 100 M
Ω
.
3.
Connect the DMM to both terminals
of the magnetron.
The test is passed if the DMM display
reads 1
Ω
or less.
4.
Using a megger/insulation tester connect to one terminal and
the metal outer case of the magnetron. The test is passed if the
megger/insulation tester display reads an infinite resistance,
"open circuit". Repeat the test for the other filament terminal
and the metal outer case.
1.
Remove all electric connections from the magnetron.
2.
Using a Digital Multi-Meter (DMM), check for continuity.
Result should be as follows: