![Welbilt Merrychef 32Z3923 Скачать руководство пользователя страница 75](http://html1.mh-extra.com/html/welbilt/merrychef-32z3923/merrychef-32z3923_service-and-repair-manual_953836075.webp)
Merrychef eikon
®
e2s service and repair manual
75
_______________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________
6 Replacing components
Back to contents >
Preparing a replacement magnetron
Removing a magnetron
1.
Carefully peal back the sealing tape on the cooling duct (keep for reuse).
2.
Unplug the magnetron high temperature thermostat(s).
3.
Unfasten the three Pozidriv screws on the right hand side of the cooling duct with a long PZ2 Pozidriv screwdriver using
the corresponding access holes at the cooling duct (when looking at the back side of the oven).
NOTE: The picture shows the right side of the cooling duct seen from the outlet of the ducting
1.
The new magnetrons come with
four pressed studs for fixing. These
studs need to be removed before
fitting the magnetron to the oven.
NOTE:
The studs can be removed by
knocking them out of the tabs with
a hammer.
Ensure the tabs are not bent
during this process. Secure them
by laying them upon a piece of
tube while pushing out the studs.
CAUTION
Wear personal protective
equipment to protect your
fingers when using the hammer.
2.
Comparison of spare
magnetrons with (right) and
without (left) pressed studs.
4.
Unfasten the one Pozidriv screw on the left side of
the cooling duct with a long PZ2 Pozidriv screwdriver
using the corresponding access hole at the cooling
duct (when looking at the back side of the oven).
NOTE: The number of screws on the left side of the
cooling duct depends on the number of magnetrons
fitted.
One magnetron (1000W e2s variant) one screw
Two magnetrons (2000W e2s variant) three screws