6.12
Adjusting the door microswitches/interlocks
Component
Adjust the microswitches after replacing old with new door hinges.
Microswitch alignment is not required if just refitting the same door, but the correct operation should be checked.
Tools required
M7 hex socket wrench
Spacer kit
Discharge Tool
Adjusting the door microswitches
Located on the oven cavity frame are 3 safety interlock microswitches, to prevent microwave emissions escaping when the
oven door is opened:
•
The primary microswitch (SW3), located on the left hand side of the oven, breaks the electrical supply circuit to the
HV transformers.
•
The secondary microswitch (SW2), located on the right hand side of the oven (outer), breaks the microwave circuit if
the primary (SW3) fails.
•
The monitor microswitch (SW1), located on the right hand side of the oven (inner), will short out the microwave circuit
blowing the F2 fuse if both secondary microswitch (SW2) fails.
IMPORTANT:
In the event that the monitor switch (SW1) causes the microwave circuit F2 fuse to blow, the secondary (SW2) and
monitor (SW1) microswitches must be replaced due to exposure to high short-circuit currents.
The purpose of the following adjustment procedure is to set the interlock to switch off the microwave circuit when the door is
opened more than 4 mm and for the microwave circuit to operate when the door is closed, and the door seal expands.
1.
Open the appliance door and position the two green 2mm spacers over the top corners of the door seal. Then
carefully close the door ensuring the spacers are still in position.
2.
Slacken the pivot nut using a M7 hex socket wrench.
Requirements
Check that the following requirements have been met:
§
The appliance has been disconnected from the power supply and protective
measures have been taken to ensure the power cannot be switched on again.
§
The appliance is cool.
§
The top and side panels of the casing of the appliance have been removed.
§
The high voltage capacitors are discharged before commencing work.