e2s service and repair manual
91
_______________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________
6 Replacing components
Back to contents >
Cavity temperature sensor (thermocouple)
Transformer (low voltage)
Capacitor(s) (high voltage)
Cavity temperature measuring is done
by a temperature sensor (thermocouple)
connected to the SRB.
The thermocouple is fitted in the rear of
the cavity from the left hand side, sealed
with a gasket and held in place by a M7
hex nut.
The low voltage transformer (ELV) is
located on the cooling duct on the left
hand side of the oven, fitted by four M5.5
hex head flange bolts
The high voltage capacitor is located on
top of the cavity and is fixed by a sheet
metal bracket and a pozidriv (PZ2) screw
The 2000W e2s variant comprises two high
voltage capacitors, again located on the
top of the cavity on each side, each
attributed to a magnetron.