5 Service information
Back to contents >
5 Service information
5.1
Service procedure
Servicing procedure: overview
1.
Disconnect/isolate the appliance from the power supply.
2.
Check the appliance is correctly installed as described in the eikon
Ò
e2s Installation and User manual.
3.
Visually check the cleanliness/condition of the power supply/cable, casing, cavity and door of the appliance for signs
of wear, damage, distortion etc. If required, refer to the “Replacing components" section of this manual (section 6).
4.
Complete an "Earth/Insulation test" (see section 5.6 of this manual) on the appliance before switching on.
5.
Check the display for error messages. If an error is shown, refer to the “Fault Finding” within section 5.3 of this manual.
6.
If a firmware update is required, follow the instructions under “Firmware updates” within section 4.5 of this manual
before continuing with the service procedure.
Touchscreen calibration
1.
Apply continuous light pressure
to the screen while switching the
appliance on. Continue to hold until
the progress bar has completed.
2.
Using a non-abrasive pointer,
such as a ball point pen, accurately
press the centre of each crosshair
displayed on the screen (ensure you
are at eye level with the screen).
3.
If the crosshair turns red you
missed the centre of the crosshair
and the calibration procedure will
start again.
4.
If the blue crosshairs turn green
three times consecutively the
calibration process is completed
successfully.
Successful procedure = 3 black
crosshairs that appear in differing
locations, followed by 3 blue
crosshairs that turn green.
5.
Once calibrated the screen will
display information about the
appliance.