26
NOTICES regarding the Manual Descaling Procedure
•
Cleveland Range recommends DISSOLVE® Descaler Solution, Part No. 106174.
•
Use no other system of steamer descaling
•
Appropriate warnings and safe handling procedures must be provided to handlers and users
•
Instructions and warnings on Dissolve® containers and Material Safety Data Sheets supersede and
replace instructions and warnings in this manual
•
General precautions: wear rubber gloves, splash goggles and other protective clothing and
equipment as necessary.
•
Refer to Dissolve® container labels and Material Safety Data Sheets for information regarding
eyewash, first aid, medical treatment, and spill control.
4) Descaling Procedure
NOTE: Descale both steam generators at the same time.
1) Turn steamer OFF and open door(s)
•
3-minute Automatic Blowdown cycle runs
2) Turn steamer ON
•
Generator begins to refill
3) Press TIMED end of TIMED/MANUAL switch (or for ON/OFF
Models put the ON/OFF selector Switch in the OFF Position
4) DO NOT start timer,
DO NOT HEAT APPLIANCE
•
Water must be cold for descaling
•
Open cooking compartment door(s)
•
Leave cooking compartment door(s) open
5) Remove descaling port cap (see Figure 6-1)
6) Add 1 gallon of Dissolve® through the descale port while
generator refills.
DANGER
The liquid solution in Cleveland Range Descaler Solution Part No. 106174 or 1061741 can
be harmful if not handled properly. Follow these basic safety rules for handling and using this
product. Instructions and warnings on container labels supersede all other warnings and
instructions.
Wear protective clothing when mixing or applying chemical cleaners
Wear rubber gloves, and OSHA approved eye protection when descaling
Avoid breathing fumes
In case of eye contact, immediately flush eyes with water for 15 minutes. If irritation persists,
seek medical attention.
In case of skin contact wash with soap and water.
If inhaled, remove to fresh air. If burning persists, call a physician.
If ingested, take 1 or 2 glasses of water and call a physician.
Figure 6-1
Descale Port