background image

STATEMENT OF RESPONSIBILITIES /

DÉCLARATION DES RESPONSABILITÉS / 

DECLARACIÓN DE RESPONSABILIDADES

This document is for use by experienced
and trained Qualified Cleveland Range,
LLC Authorized Service Representatives
who are familiar with both the safety
procedures, and equipment they
service. Cleveland Range, LLC assumes
no liability for any death, injury,
equipment damage, or property damage
resulting from use of, improper use of,
or failure to use the information
contained in this document. Cleveland
Range, LLC has made every effort to
provide accurate information in this
document, but cannot guarantee that
this document does not contain
unintentional errors and omissions.

The information in this document may
be subject to technical and
technological changes, revisions, or
updates. Cleveland Range, LLC
assumes no liability or responsibility
regarding errata, changes, revisions, or
updates.

Qualified Cleveland Range, LLC
Authorized Service Representatives are
obligated to follow industry standard
safety procedures, including, but not
limited to, OSHA regulations, and
disconnect / lock out / tag out
procedures for all utilities including
steam, and disconnect / lock out / tag
out procedures for gas, electric, and
steam powered equipment and / or
appliances.

All utilities (gas, electric, water and
steam) should be turned OFF to the
equipment and locked out of operation
according to OSHA approved practices
during any servicing of Cleveland Range
equipment

Qualified Cleveland Range, LLC
Authorized Service Representatives are
obligated to maintain up-to-date
knowledge, skills, materials and
equipment. 

Ce document est destiné à l’usage des
Représentants de Service qualifiés et
autorisés de Cleveland Range, LLC qui
possèdent l’expérience et la formation ainsi
que la bonne connaissance des mesures
de sécurité et du matériel qu’ils
entretiennent.

Cleveland Range, LLC décline toute
responsabilité pour tout cas de décès,
blessure, dommage matériel ou dommage
aux biens résultant de l'utilisation, de la
mauvaise utilisation ou du manquement
d’utilisation des renseignements contenus
dans ce document.

Cleveland Range, LLC s’est efforcé à
fournir des renseignements précis dans ce
document mais ne peut garantir que ce
document soit exempt d’erreurs et
d’omissions non intentionnelles. 

Les renseignements contenus dans ce
document peuvent être assujettis à des
changements techniques et technologiques,
des révisions ou des mises à jour. 

Cleveland Range, LLC décline toute
obligation ou responsabilité concernant les
errata, modifications, révisions ou mises à
jour.

Les Représentants de Service qualifiés et
autorisés de Cleveland Range, LLC sont
tenus de se conformer aux mesures de
sécurité normalisées de l’industrie, y
compris, mais sans s'y limiter, les
réglementations de l'OSHA, les procédures
de  débranchement / verrouillage /
étiquetage relatives à tous les services
publics, dont l’approvisionnement en
vapeur, et les procédures de
débranchement / verrouillage / étiquetage
relatives aux équipements et/ou appareils
fonctionnant au gaz, à l’électricité et à la
vapeur.

Au cours de tout entretien d’un appareil
Cleveland Range, tous les services publics
(gaz, électricité, eau et vapeur) doivent être
FERMÉS au niveau de l’appareil et le
dispositif de fonctionnement doit être
verrouillé suivant les pratiques approuvées
de l’OSHA.

Les Représentants de Service qualifiés et
autorisés de Cleveland Range, LLC sont
tenus d’actualiser en permanence leurs
connaissances, compétences, matériel et
équipement.

Este documento está destinado para el uso
de los Representantes de Servicio
calificados y autorizados de Cleveland
Range, LLC quienes cuentan con la
experiencia y la capacitación así como el
buen conocimiento de las medidas de
seguridad y de los equipos que mantienen. 

Cleveland Range, LLC, declina toda
responsabilidad en caso de cualquier
fallecimiento, lesiones, daños al equipo o
daños a la propiedad resultantes de la
utilización, del uso indebido o de la falta de
utilización de la información provista en este
documento.

Cleveland Range, LLC se ha esforzado en
suministrar información precisa en este
documento, pero no puede garantizar que
este documento esté exento de errores y de
omisiones no intencionales.

La información contenida en este
documento podría estar sujeta a cambios
técnicos o tecnológicos, revisiones o
actualizaciones.  Cleveland Range, LLC
declina toda obligación o responsabilidad
con respecto a erratas, modificaciones,
revisiones o actualizaciones.

Los Representantes de Servicio calificados y
autorizados de Cleveland Range, LLC tienen
la obligación de seguir los procedimientos
estándar de seguridad de la industria; los
cuales incluyen pero no se limitan a los
reglamentos de la OSHA (La Administración
de la Seguridad y Salud Ocupacionales), los
procedimientos de desconexión, cierre y
etiquetado relativos a todos los servicios
públicos incluyendo el suministro de vapor y
los procedimientos de desconexión, cierre y
etiquetado para los equipos y/o aparatos
que funcionan a base de gas, electricidad o
vapor.

Cuando se esté dando servicio o
mantenimiento a un aparato de Cleveland
Range, todos los servicios públicos (gas,
electricidad, agua y vapor) deben estar
APAGADOS para el equipo en cuestión y se
debe seguir el procedimiento de cierre de
operaciones de acuerdo con las prácticas
aprobadas por la OSHA.

Los Representantes de Servicio calificados y
autorizados de Cleveland Range, LLC tienen
la obligación de actualizar constantemente
sus conocimientos, destrezas, materiales y
equipamiento.

Содержание Cleveland SteamCraft 24CEA10

Страница 1: ...ation Installation Maintenance Manual This manual is updated as new information and models are released Visit our website for the latest manual MODEL 24CEA10 For your future reference Model __________...

Страница 2: ...nformer aux mesures de s curit normalis es de l industrie y compris mais sans s y limiter les r glementations de l OSHA les proc dures de d branchement verrouillage tiquetage relatives tous les servic...

Страница 3: ...juste modificaci n servicio o mantenimiento puede ocasionar da os a la propiedad lesiones o muerte Lea detenidamente las instrucciones de instalacion y de operaci n antes de instalar poner a funcionar...

Страница 4: ...de presi n Keep clear of pressure relief discharge Restez l cart de la soupape de suret Permanezca alejado de la descarga de presi n Do not lean on or place objects on the equipment Ne vous penchez p...

Страница 5: ...e Start Up and Shutdown Summary Instructions 4 B Control Panel Switches 5 C Operating and Cooking Procedure 6 D Timed Mode Operating and Cooking Procedure 6 E Manual Mode Operating and Cooking Procedu...

Страница 6: ...st for Dial Timer Control Panel 21 E Timer Test for Keypad Control Panel 22 F General Information about the Compartment Door Optional Steam Cut Off Switch 23 G Function Test for the Compartment Door O...

Страница 7: ...as applicable When installed the appliance must be electrically grounded in accordance with the above b The Food Code latest edition of the Food and Drug Administration FDA 2 This equipment is to be i...

Страница 8: ...IAL NUMBERS 1 Cleveland Range LLC assigns two product identification numbers to each appliance a model number and a serial number 2 Please provide this information when you contact Cleveland Range or...

Страница 9: ...tment door and reduced cooking performance To help avoid injury When checking inside the cooking compartment always stand to the hinge side and away from the appliance and open the door slowly Inspect...

Страница 10: ...s For ON OFF controls Turn ON the Compartment Steam switch 3 Turn ON the ON OFF switch See figure 4 1 The steam generators fill with water in about 6 minutes 4 Turn ON one or both cooking compartment...

Страница 11: ...CONTROL PANEL SWITCH Figure 4 1 1 POWER ON and GENERATOR FILL Switch with Power ON Indicator Light This is the ON OFF switch Turn this switch ON to power the control panel and fill the steam generato...

Страница 12: ...door to maintain cooking compartment temperature b If another use is not planned for more than half an hour leave the cooking compartment door open slightly c If the appliance will not be used again d...

Страница 13: ...perating time from 0 to 60 minutes Turn the knob clockwise until it points to the required time When the Timer reaches 0 a buzzer sounds for 3 seconds The Dial Timer does NOT work in Manual Mode 2 TIM...

Страница 14: ...er after it has been stopped The Timer must rest to zero 00 00 zeroed by pressing this key before a new time can be set 4 START STOP Key Press this key to start and stop the Timer Press and hold for 5...

Страница 15: ...ndards blowdown must be performed at the end of each shift 3 Blowdown Procedure a Follow the Shut Down instructions in Chapter 4 b EITHER restart the appliance by following the Startup instructions in...

Страница 16: ...nd lifting up and away from the door b Wipe the gasket assembly with a damp cloth c Wipe the inside of the door with a damp cloth d Rotate the gasket assembly 180 This makes the gasket last longer e R...

Страница 17: ...l If this appliance is suspected to be out of level shut it down at once and call your qualified Cleveland Range authorized service agency immediately CHAPTER 6 GENERAL INSTALLATION INFORMATION A Insp...

Страница 18: ...rances and the Exhaust Hood Refer to spec sheet for more details g KEEP THE APPLIANCE AREA FREE AND CLEAR OF COMBUSTIBLES h Proper air supply for ventilation is REQUIRED for and CRITICAL to safe effic...

Страница 19: ...Check the quality of supply water before designing the water supply by contacting a local water treatment specialist for on premises water analysis d Softened or chlorinated water damages the steam ge...

Страница 20: ...use the Separate Feed Water Supply Arrangement shown in Figure 3 3 Figure 3 2 Cleveland Range Single Water Supply Arrangement Figure 3 3 Cleveland Range Separate Water Supply Arrangement Conditioned i...

Страница 21: ...ic Power Supply The electric supply must match all electrical and wiring requirements specified on the rating plate NOTE The 24CEA10 Electrical Diagram is located inside of the Condensate Drip Trough...

Страница 22: ...connect the appliance s drain connection to any drain material that cannot sustain 180o F 6 Do NOT connect any other drain from any other equipment to the drain line of this appliance 7 Do NOT connec...

Страница 23: ...es Ch 7 Test Supply Water Quality Warranty Ch 7 Water Supply Requirements Met Ch 7 Electric Power Requirements Met Rating Plate Ch 7 Installation Ch 7 Check Level Front to Back and Side to Side Ch 7 C...

Страница 24: ...est Startup and Shutdown Instructions NOTE Perform this test before Startup Test Procedure A Startup Instructions 1 If not already done Test the water supply lines Leaks and pressure 2 Turn the Main E...

Страница 25: ...r the Main External Power Switch OFF 2 Check the fuses or circuit breakers for proper size 3 Make sure the water supply line valves are open 4 Open the cooking compartment doors Check for proper insta...

Страница 26: ...ater column float assembly are flushed with fresh water 7 Stop the blowdown cycle before it is complete by turning the ON OFF switch ON a The operating controls energize b The red ON indicator in the...

Страница 27: ...The red indicator in the ON OFF switch turns OFF Automatic blowdown starts and runs for 3 minutes 2 After blowdown ends a Turn OFF the Main External Power Switch b Replace all panels and sheeting c Tu...

Страница 28: ...ors 5 Set the TIMED MANUAL switch to TIMED a Press the number keys 1 0 0 0 b The display reads 10 00 ten minutes and zero seconds 6 Press the START STOP key The timer reads PAUS pause The cooking comp...

Страница 29: ...1 Start the appliance with both cooking compartments in MANUAL mode 2 Wait for the cooking compartments to reach cooking temperature 3 Stand to the hinge side and back from the upper door and careful...

Страница 30: ...ckage of the drain line can cause pressure buildup in the compartment s resulting in steam leaks around the door gasket s reduced performance and compartment implosion 2 To inspect the drain screens a...

Страница 31: ...ase of eye contact immediately flush eyes with water for 15 minutes If irritation persists seek medical attention In case of skin contact wash with soap and water If inhaled remove to fresh air If bur...

Страница 32: ...N OFF Models put the ON OFF selector Switch in the OFF Position 4 DO NOT start timer DO NOT HEAT APPLIANCE Water must be cold for descaling Open cooking compartment door s Leave cooking compartment do...

Страница 33: ...FF to start 3 minute Automatic Blowdown to rinse generator 13 Replace descaling cap and close cooking compartment door s 14 Turn TIMED MANUAL switch to TIMED 15 Turn steamer ON OFF switch to ON and se...

Страница 34: ...MANUAL or TIMED modes Water supply to steamer shut OFF Open water supply valves Door interlock switch not engaged or has failed if unit has this option Close door completely If problem persists see No...

Страница 35: ...ed wiring See Note 1 Water is flowing out of steam ports into cooking compartment See Warning under Note 9 Water probes are dirty Turn OFF water supply to steamer and descale steamer manually with Cle...

Страница 36: ...r Cleveland Range Please have the model number and serial number ready when calling Cleveland Range will not pay for warranty repairs by unauthorized maintenance and repair centers 2 Proper installati...

Страница 37: ...m if needed Failure to follow these precautions can cause burns scalds and equipment damage EGG SIZE CHART Egg Size Time Medium 10 minutes Large 12 minutes Extra Large 12 minutes 3 When time is comple...

Страница 38: ...itchencare com To learn how Welbilt Foodservice and its leading brands can equip you visit our global web site at www welbilt com then discover the regional or local resources available to you Every n...

Отзывы: