25
CAUTION
Do not use any other product or method of descaling other than the
DISSOLVE
®
Descaler method using Part No. 106174.
•
Use no other system of descaling.
3) Manual Method to Descale Steam Generator
NOTE:
Part No. 106174 is the Part No. for a case (6 1-gallon containers) of
DISSOLVE
®
descaler.
THESE INSTRUCTIONS ARE FOR USE WITH
DISSOLVE
®
DESCALER SOLUTION
Cleveland Range Part No. 106174.
•
Health Hazard Data, Effects of Overexposure
– This product may cause a burning sensation to eyes or skin.
•
Emergency and First Aid Procedures
–
In case of eye contact, immediately flush eyes with water for 15 minutes. If irritation
persists seek medical attention.
–
In case of skin contact wash with soap and water.
–
If inhaled, remove to fresh air. If burning persists, call a physician.
–
If ingested, take 1 or 2 glasses of water and call a physician.
•
Spill or Leak Procedures
–
Rinse with plenty of water to dilute.
–
Sodium carbonate or calcium carbonate may be used to soak up liquid.
–
Considered non-hazardous, spent material may be disposed of in a sewer system with
water flush.
WARNING
Descaling procedure is slightly different depending on model. This
entire procedure should be read and fully understood as it applies to
the model being descaled, before beginning descaling operations.