14
SteamCraft
Water Connection
Air/Water Column
(if required)
Check Valve
Y-Strainer
Condenser Solenoids
Main Cold
Water Supply
Generator Fill Solenoid
Water Connection
Pressure Reducer
(if required)
Main Water
Shutoff Valve
SteamCraft
Condenser Solenoids
Generator Fill Solenoid
Water Connection
Y-Strainer
Check Valve
Air/Water Column
(if required)
Cold Tap Water
Supply
Pressure Reducer
Main Water
Water Connection
(if required)
Shutoff Valve
Conditioned* Cold
Water Supply
b. If the static pressure is above 60 psi, a pressure regulator must be used and set at
approximately 50 psi. Pressure above 60 psi can damage solenoid valves. See Figures
3-2 and 3-3.
c. If the supply water meets the requirements shown in the Warranty, then the Single Water
Supply Arrangement shown in Figure 3-2 may be used.
1) If using the single water supply arrangement: The supply piping to the tee fitting must be
at least the next larger size of pipe than the connection provided on the appliance.
d. If the water supply fails to meet the requirements shown in the Warranty, then use the
Separate Feed Water Supply Arrangement shown in Figure 3-3.
Figure 3-2 Cleveland Range Single Water Supply Arrangement
Figure 3-3 Cleveland Range Separate Water Supply Arrangement
* “Conditioned” indicates water that has been filtered or treated by a Cleveland Range approved
method to meet or exceed the water quality standards in the Warranty.
e.
Installation Requirements:
•
Apply non-hardening pipe thread sealant to threaded connections.
•
The 24CEA10 has two 3/8” NPT female fittings its underside: one for the steam generators
(treated water) and one for the condenser (cold water). Refer to spec sheet for more details.
•
Install a manual water shut-off valve (Main Water Shutoff Valve) (not provided) between the cold
water supply line(s) and the appliance.
•
The National Sanitation Foundation (NSF) requires installation of a check valve (or other
approved anti-backflow / anti-siphon device) (not provided) in all supply lines in accordance with
and
as required by local, state, and national health, sanitation and plumbing codes.
•
When using the Separate Water Supply Arrangement, use two water strainers. Order extra water
strainers from Cleveland Range or your Authorized Sales Representative.
•
Flush the water supply lines before connecting the lines to the appliance.