24
CHAPTER 10 PREVENTATIVE MAINTENANCE
A. General Information
•
Follow the maintenance instructions and schedules to help keep the appliance working properly.
•
Increase the frequency of maintenance as needed depending on use and water quality.
•
Contact your qualified Cleveland Range authorized service agency or Cleveland Range for more
information about maintenance scheduling, products, and services.
B. Maintenance and Service Records
1. Make a file just for maintenance records.
2. Keep a written record of daily, weekly, monthly, and yearly maintenance, service, and repair. Each
record must include at least:
•
The date of the service, maintenance, or repair.
•
A description of the service, maintenance, or repair performed.
•
Copies of purchase order(s) and invoice(s) for repair parts and service, maintenance, or
repair. Include part numbers, if applicable.
•
The name and signature of the person performing the service, maintenance, or repair.
C. Daily Maintenance
1. Blowdown
•
Blowdown the steam generator. Follow the instructions in Chapter 5.
2. Clean the Appliance
•
Clean the interior and exterior of the appliance. Follow the instructions in Chapter 5.
D. Weekly Maintenance
1. Clean the Cooking Compartment Drains
•
Blockage of the drain line can cause pressure buildup in the compartment(s) resulting in
steam leaks around the door gasket(s), reduced performance, and compartment implosion.
2. To inspect the drain screens and the drain lines for blockage:
a. Clean the cooking compartment and drain screens. Follow the instructions in Chapter 5.
b. Rotate the drain screen 90 degrees to inspect the drain opening.
c. Clean the opening and put the screen back into their operating position.
d. Pour a quart of water into the cooking compartment. If the water drains slowly or stands,
clean the cooking compartment drains with a NSF/FDA approved drain cleaner.
•
Follow the instructions of the drain cleaner manufacturer.
•
Flush the cooking compartments and drains with clean water.
E. Monthly Maintenance
1) Descale the Steam Generator
•
Steam Generators should be descaled once a month, or more often depending on scale buildup.
•
Note the date of decaling in your maintenance and service records to help keep Steam
Generator descaling on schedule.
2) SteamCraft Power 10 Descaling Procedure Using the Descaling Pump System
•
Cleveland Range recommends that your service agency descales your 24CEA10
•
If you have trained and skilled in-house maintenance personnel, you may wish to discuss
purchasing Descaling Pump System P/N: 1071421 for use with Dissolve® Descaler Solution
P/N 106174 with your sales representative or service agency.