15
Figure 3-9
Hardwire Connection
SteamCraft
DRAIN LINE
COLD WATER SUPPLY LINES
MAIN EXTERNAL
POWER SWITCH
1) Test Water Supply Lines
a. Check all connections for proper tightness.
b. Inspect the water connections inside the appliance. (Remove side panels if not already off.)
c. Open the water supply valves.
d. Check all lines and connections for leaks, both inside and outside the appliance.
E. Electric Power Supply
•
The electric supply must match all electrical and wiring requirements specified on the rating plate.
•
NOTE: The 24CEA10 Electrical Diagram is located inside of the Condensate Drip Trough.
The connection must be made as follows:
1. Install a main disconnect switch and a separate fuse or breaker for this appliance as shown in
Figure 3-8. The fused disconnect switch is referred to as the “Main External Power Switch.”
2.
Do NOT use a power cord.
3. Make the electrical connection using flexible conduit, per local code. See Figure 3-9.
Figure 3-8
Electrical Layout
Ground Lug
Terminal Block