Installation and operating instruction
Gas condensing unit WTC-GB 15-B Compact and WTC-GB 25-B Compact
6 Operation
83309302 1/2018-05 La
72-196
6.6.1.6 Domestic hot water
Info
Domestic hot
water
Information
Description
1.7.1
Status
Current operating mode of DHW circuit.
Standby via system program switch
Time program - normal
Time program - setback
DHW mode activated
Normal, setback, standby via input H2
1.7.2
Flow setpoint
temperature DHW
Required flow setpoint temperature for DHW loading.
The flow set temperature results from the
DHW setpoint temperature
and
the
flow setpoint temperature increase
(P
7.1.3
).
1.7.3
DHW setpoint
temperature
DHW setpoint temperature of current operating mode (normal or setback).
1.7.4
DHW temperature
Current temperature at the DHW sensor (B3).
1.7.5
Return flow temperature
circulation
Current temperature at the return flow sensor (T1) of the circulation line.
Only on compact version WAS 100.
1.7.6
DHW pump
Current operating mode of DHW load pump.
Off
On
1.7.7
Status DHW mode
Current operating mode of DHW circuit.
Off
Standby
Burner start
Tap operation
Comfort keep warm function
Top-up heating following tap drawdown
Pump run-on
SCOT calibration in DHW
1.7.8
DHW outlet setpoint
temperature
Required setpoint of DHW outlet temperature.
1.7.9
DHW actual outlet
temperature
Current temperature at the DHW outlet sensor (T1).
Only on compact version WAS … Power.
1.7.12
DHW
temperature bottom
Current temperature at the DHW sensor switch-off (T2).
Only on compact version WAS … Power.