Installation and operating instruction
Gas condensing unit WTC-GB 15-B Compact and WTC-GB 25-B Compact
6 Operation
83309302 1/2018-05 La
70-196
6.6.1.5 Heating circuits
Info
Heating
circuits
A separate submenu appears for each heating circuit.
Information
Description
1.6.1
Operating mode
Current operating mode of heating circuit.
System standby; system Summer
Function specific heating; screed drying
Holiday
Time program 1 … 3
Summer; setback; normal; comfort
1.6.2
Status
Current status of the operating mode of the heating circuit.
Room frost protection
Emergency-Off
Day …
Special, comfort, normal, setback, standby via input H1
Party
On optimisation
Level increase external temperature
Excess temperature alternative energy
Excess alternative energy
DHW priority
Summer operation weather compensated
Heating limit shutdown room
Heating limit shutdown flow
Thermostat shutdown
Comfort; normal; setback
Frost protection on
1.6.3
External temperature
– or –
1.6.3
Local external temper-
ature
Current temperature at external sensor (B1) or at external sensor (T1) on heating
circuit extension module (
local
).
Show additional information:
Press dial knob.
Current
:
Current external temperature used for system frost protection.
Damped
:
Tendency of the outdoor temperature used for the summer-winter changeover.
Mixed
:
Calculated outdoor temperature (current and damped) used for the flow setpoint
temperature.
1.6.4
Room setpoint temperat-
ure
Room setpoint temperature of currently activated temperature level.
1.6.5
Flow setpoint temperat-
ure
Required flow setpoint temperature of the heating circuit.
1.6.6
Actual flow temperature
Current temperature at flow sensor (B6) of the heating circuit.
1.6.7
Mixer setpoint setting
Required setting of mixer valve.
1.6.8
Actual mixer setting
Actual setting of mixer valve.