Installation and operating instruction
Gas condensing unit WTC-GB 15-B Compact and WTC-GB 25-B Compact
5 Installation
83309302 1/2018-05 La
41-196
If a gas safety valve is required:
Connect valve to output MFA1 or VA1/2, see [ch. 5.7.1].
Set output to
Gas safety valve
5.4 Install condensing unit
Remove front panel
The front panel is secured with a screw at the tension lock to prevent accidental
opening.
Refit screw when mounting front panel.
Remove screw
1
from tension lock at the underside of the unit.
Open the tension lock and remove the front panel.
1
Mount condensing unit
Mount the unit, making sure that the guide pins
1
are located within the fresh
water storage tank.
Slide the unit on the slide rails
2
to the rear.
Secure the unit with knurled screws
3
.
1
1
3
3
2
Fit side panel (accessory) to the condensing unit.