Installation and operating instruction
Gas condensing unit WTC-GB 15-B Compact and WTC-GB 25-B Compact
7 Commissioning
83309302 1/2018-05 La
110-196
11. Assign room device 1 (optional)
Each room device must be assigned with an operating access and if the control is
room temperature controlled, a room sensor must be assigned.
Room device 1 can operate one heating circuit.
Select relevant room device.
Press dial knob.
Assign desired operating access for heating circuit.
If required, assign desired room sensor assignment for heating circuit.
Repeat procedure for the other room devices.
Assignment RG1
Assign room device to a heating circuit.
Room device 1
0000000041
Room device 1
0000000042
02
01
Assignment RG1
Device information
HC operating access
1
Heating circuit 1
Room sensor
assignment
Heating circuit 1
1
0000000041
Select
and confirm.
12. Assign room device 2 (optional)
Each room device must be assigned with an operating access and if the control is
room temperature controlled, a room sensor must be assigned.
Room device 2 can operate up to 3 heating circuits and one DHW circuit.
Select relevant room device.
Press dial knob.
Assign desired operating access for heating circuit and DHW circuit.
If required, assign desired room sensor assignment for heating circuit.
Repeat procedure for the other room devices.
Assignment RG2
Assign room device to the heating and DHW
circuits.
Room device 2
0000000023
Room device 2
0000000024
02
01
Assignment RG2
Device information
HC operating access
1
Heating circuit 1
HC operating access
2
EM heating circuit 2
HC operating access
3
--
1
0000000023
Select
and confirm.