上海维宏电子科技股份有限公司
Weihong Electronic Technology Co., Ltd.
- 66 - Specialized, Concentrated, Focused
Parameter
Meaning
Setting Range
Enable
AQE
compensation
Whether
to
enable
AQE
compensation
Yes: Valid
No: Invalid
AQE compensation time
-
0 ~ 0.3 (sec)
AQE
compensation
length
-
0 ~ 10 (mm)
Delay
time
of
AQE
compensation
-
0 ~ 10 (sec)
Intensity
of
AQE
compensation
-
0 ~ 1
To enable AQE compensation, set parameter
―Enable AQE compensation‖ as ―Yes‖.
Compensation time: the larger the value is, the larger the compensation-affected area will be.
Recommended value is 0.02 sec.
Compensation length: the larger its value is, the more obvious the compensation result will be.
However, note that too large value will make the arc concaved, while too small value will not
suppress the spike effectively. It is suggested to measure the actual height of the spike with a laser
interferometer or other measuring device in debugging, and then set this parameter as 0.3 to 3
times of spike height. Compensation result is also related with compensation time and intensity.
Compensation delay time: the spikes may not appear exactly at the four quadrant positions due to
mechanical properties of machine tool, but a little distance away from the quadrant points. Estimate
the time to travel this distance and then set the time as the value of this parameter.
Compensation intensity: the larger the value is, the more obvious the compensation result will be.