上海维宏电子科技股份有限公司
Weihong Electronic Technology Co., Ltd.
- 148 - Specialized, Concentrated, Focused
Name
Setting Range
Default
Value
When
Enabled
Refer-
ence
mouse or keyboard input
X axis coordinate of the
fixed point
The upper limit of table travel~
The lower limit of table travel
(mm)
0
Immediately
Y axis coordinate of the
fixed point
0
Immediately
Z axis coordinate of the
fixed point
-1
Immediately
A axis coordinate of the
fixed point
-1
Immediately
G73_G83 retract amount
0~9999.9 (mm)
0
Immediately
Pause Z Offset
-(mm)
10
After restart
X direction in backing to
reference point
-1,1
-1
Immediately
Y direction in backing to
reference point
-1,1
-1
Immediately
Z direction in backing to
reference point
-1,1
-1
Immediately
A direction in backing to
reference point
-1,1
-1
Immediately
Retract distance of X axis -(mm)
2
Immediately
Retract distance of Y axis
-(mm)
2
Immediately
Retract distance of Z axis
-(mm)
-2
Immediately
Retract distance of A axis
-(mm)
-2
Immediately
X speed in backing to
reference point
0.001~MAX
Axial
Velocity
(mm/min)
1800
Immediately
Y speed in backing to
reference point
0.001~MAX
Axial
Velocity
(mm/min)
1800
Immediately
Z speed in backing to
reference point
0.001~MAX
Axial
Velocity
(mm/min)
1500
Immediately
A speed in backing to
reference point
0.001~MAX
Axial
Velocity
(mm/min)
1500
Immediately
X
speed
in
exact
positioning
0.001~15000(mm/min)
200
Immediately
Y
speed
in
exact
positioning
0.001~15000(mm/min)
200
Immediately
Z
speed
in
exact
positioning
0.001~15000(mm/min)
100
Immediately
A
speed
in
exact
positioning
0.001~15000(mm/min)
100
Immediately
X axis screw pitch
0.001~9999.9 (mm)
5
Immediately
Y axis screw pitch
0.001~9999.9 (mm)
5
Immediately
Z axis screw pitch
0.001~9999.9 (mm)
5
Immediately
A axis screw pitch
0.001~9999.9(mm)
5
Immediately
Open auto lubrication
Yes: Valid
No: Invalid
No
Immediately -
Interval
of
opening
lubrication
0~34560000(sec)
18000
Immediately -
Opening
time
of
lubrication pump
0~34560000(sec)
5
Immediately -
Cycle machining interval
0~3600000(sec)
0
Immediately -
Enable Y as revolving
axis
Yes: Valid
No: Invalid
No
After restart
-