上海维宏电子科技股份有限公司
Weihong Electronic Technology Co., Ltd.
- 146 - Specialized, Concentrated, Focused
Name
Setting Range
Default
Value
When
Enabled
Refer-
ence
-1: Negative direction
Axis output direction (Z)
1: Positive direction
-1: Negative direction
1
After restart
Axis output direction (A)
1: Positive direction
-1: Negative direction
1
After restart
Safety Height
0~5000 (mm)
10
Immediately
Single Axis Acc
0.001~100000 (mm/ s
2
)
1200
Immediately
Delay time of acute angle
motion
-(ms)
0
Immediately
-
Startup Speed
0~Z-axis Approach Speed (mm/
min)
100
Immediately
Rough
Speed
of
Calibration
1 ~ Rapid JOG Feedrate
(mm/min)
400
Immediately
Calibration
Block
Thickness
0~100 (mm)
10
Immediately
X Coor of Fixed Cali Block Negative Travel Limit (MCS) ~
Positive Travel Limit (MCS)
(mm)
0
Immediately
Y Coor of Fixed Cali Block
0
Immediately
Z Coor of Fixed Cali Block
-1.0
Immediately
Handwheel
Output
Direction
-1: Opposed to axis output
direction
1: Same as axis output direction
1
After restart
Handwheel
in
strict
accordance with the pulse
counting
Yes: Valid
No: Invalid
No
After restart
Acceleration of handwheel 0~100000
200
After restart
Full Feedrate for G00
Yes: Fixed
No: Not fixed
Yes
After restart
Feedrate
is Valid
for
Manual Mode
Yes: Valid
No: Invalid
Yes
After restart
Use Default Speed
Yes: Valid
No: Invalid
Yes
Immediately
Use
Default
Spindle
Speed
Yes: Valid
No: Invalid
Yes
Immediately
Back
to
REF
before
machining
Yes: Valid
No: Invalid
Yes
Immediately
Cancel REF Sign on
Estop
Yes: Valid
No: Invalid
Yes
Immediately
Is reset SVON when estop
Yes: Valid
No: Invalid
No
Immediately
MAX Angle of Joining
High Speed
0~180.001 (deg)
120
Immediately
-
Corner
Trace
Pretreatment Options
0: Not disposed
1: Curve smooth
2: Arc smooth
0
Immediately
-
Corner tolerance
0~0.5 (mm)
0.1
Immediately
-
Connect
speed
look
ahead distance
0~0.05 (mm)
0.05
Immediately
-
Predicted segment No.
1~100
50
Immediately
Whether to Use S-type
Algorithm
Yes: Valid;
No: Invalid
1
Immediately
Plunge Speed Options
0: No limitation
1: Z Down Feedrate Limitation
valid with only Z-axis downward
0
Immediately
-