上海维宏电子科技股份有限公司
Weihong Electronic Technology Co., Ltd.
Specialized, Concentrated, Focused - 121 -
Para.
No.
Function
Format &
Range
Value
Description
output as NC (normally closed) b-contact
point;
X1X0=08: set pin 1 and pin 26 as BK+ and
BK- respectively.
P2-22
Function setting
for digital output
pin DO5
X2X1X0
007
DO5 corresponds to pin 28 & pin 27, used
as servo alarm signal.
X2=0: set DO5 output as NC b-contact
point.
X1X0=07: set pin 28 and pin 27 as ALRM+
and ALRM- respectively.