上海维宏电子科技股份有限公司
Weihong Electronic Technology Co., Ltd.
- 118 - Specialized, Concentrated, Focused
Para.
No.
Function
Format &
Range
Value
Description
open) a-contact point; X2=0: set DO4
output as NC (normally closed) b-contact
point;
X1X0=08: set pin 1 and pin 26 as BK+ and
BK- respectively.
P2-22
Function setting
for digital output
pin DO5
X2X1X0
007
DO5 corresponds to pin 28 & pin 27, used
as servo alarm signal.
X2=0: set DO5 output as NC (normally
closed) b-contact point.
X1X0=07: set pin 28 and pin 27 as ALRM+
and ALRM- respectively.
P2-51
Servo ON (SON)
setup
0
0: Servo ON must be triggered by
numerical input signal.
1: when servo is powered, if there is no
alarm signal, servo will be automatically on.
Set 1 when there is no SON signal wire.