Section 4
Auto-Zone Plus
4-4
Start-Up and Troubleshooting
The Network communications loop should only be connected to the MiniLink’s Network
terminals on the Zone Manager(s), and the CommLink II.
All communications wiring should be labeled to avoid confusion and to aid future
servicing.
I15.CDR 10/29/96
LINE
LINE
LINE
LINE
LINE
NETWORK LOOP
WATTMASTER CONTROLS, INC.
COMM LINK II
COMM LINK II
INTERFACE
( MULTIPLE LOOP VERSION )
COMPUTER
(OPTIONAL)
Remote Link
(OPTIONAL)
NET
WORK
LOOP
LOCAL LOOP #1
HVAC UNIT #1
ZONE MANAGER
CLUSTER ADDRESS
SWITCH SET TO 1
RS-485 COMM LOOP
ZONE
CONTROLLER
#1
ZONE
CONTROLLER
#16
CONSTANT VOLUME
CONTROLLER
( IF USED )
COMM
PWR
COMM
PWR
RELAY
OUTPUT
COM
1-3
OUT
OUT
1
2
COM
4-5
OUT
OUT
OUT
3
4
5
24VAC
GND
PWR
COMM
T
SHLD
LD4
REC.
12V
AIN
1
2
3
4
5
GND
GND
AOUT
AIN
AIN
AIN
AIN
4-5
OUT
COMM
TEST
32K
8K
RAM
EPROM
ADDRESS
ADD
PRESSURE
SENSOR
485
COMM
R
YS101564
E
W
D
OG
0-5 VD
C
0-1 VD
C
TO ANY ADDITIONAL
CV CONTROLLER OR
ADD ON DEVICES
NET
WORK
LOOP
LOCAL LOOP #2
HVAC UNIT #2
ZONE MANAGER
CLUSTER ADDRESS
SWITCH SET TO 2
ZONE
CONTROLLER
#1
ZONE
CONTROLLER
#16
CONSTANT VOLUME
CONTROLLER
( IF USED )
COMM
PWR
COMM
PWR
RELAY
OUTPUT
COM
1-3
OUT
OUT
1
2
COM
4-5
OUT
OUT
OUT
3
4
5
24VAC
GND
PWR
COMM
T
SHLD
LD4
REC.
12V
AIN
1
2
3
4
5
GND
GND
AOUT
AIN
AIN
AIN
AIN
4-5
OUT
COMM
TEST
32K
8K
RAM
EPROM
ADDRESS
ADD
PRESSURE
SENSOR
485
COMM
R
YS101564
E
W
D
O
G
0-5 VDC
0-1 VDC
TO ANY ADDITIONAL
CV CONTROLLERS OR
ADD ON UNITS
ADDRESS=17
ADDRESS=17
WATTMASTER CONTROLS INC.
WATTMASTER CONTROLS INC.
Override
Communication
Communication
Alarm
9
8
7
CLEAR
0
DEC.
MINUS
ENTER
NO ALARM(S)
NO ALARM(S)
06/11/96 03:38PM FRI
06/11/96 03:38PM FRI
AUTOZONE COOL MODE
AUTOZONE COOL MODE
2
5
4
1
6
3
OCCUPIED
MENU
ESC
ESC
SYSTEMMANAGER
SYSTEM MANAGER
Line
Line
Figure 4-2:
Communications Loop Routing
1.2.1
Communications Checklist
•
All Zone Managers are set to address
17
•
Each Local loop has a unique cluster address
•
Zone Controllers are addressed from 1 to 16
•
CV Units are addressed from 18 to 30
•
Power has been cycled after changing addresses
•
A CommLink II is powered and connected to the Network loop
•
Be sure Local loops are
not
connected to each other
•
System Manager is connected to a Local loop,
not the network loop
firealarmresources.com
Содержание Auto-Zone Plus
Страница 1: ...Design Installation And Operations Manual Plus System Revision 02B firealarmresources com...
Страница 2: ...firealarmresources com...
Страница 4: ...firealarmresources com...
Страница 6: ...firealarmresources com...
Страница 68: ...firealarmresources com...
Страница 116: ...firealarmresources com...
Страница 124: ...Section 4 Auto Zone Plus 4 6 Start Up and Troubleshooting Figure 4 4 Local Loop Wiring firealarmresources com...
Страница 155: ...Auto Zone Plus Section 4 Start Up and Troubleshooting 4 37 Notes firealarmresources com...
Страница 177: ...Auto Zone Plus Section 4 Start Up and Troubleshooting 4 59 Notes firealarmresources com...
Страница 178: ...Section 4 Auto Zone Plus 4 60 Start Up and Troubleshooting Notes firealarmresources com...
Страница 179: ...Auto Zone Plus Section 4 Start Up and Troubleshooting 4 61 Notes firealarmresources com...