TROUBLESHOOTING
No Cold Water Available
Possible Reason
Solution
Closed Water Supply Valve
Open the Water Supply Valve
Cold Water Solenoid Valve
malfunction
Inspect the valve components for proper functionality.
Green Heater and Compressor
Switch on unit is off.
Turn Green Heater/ Compressor Switch on.
I = ON
Loose connection(s) on the
Display PCB
Turn power off; unplug the unit and visually inspect solenoid
connections into the Display PCB. Verify the soldering points
on connections are secure into the board.
Remove the PCB to inspect the front of the board.
Exhausted Filter
Replace filters as needed.
WL400
Operating, Installation, and Service Manual Page 64 - Revision: 5-29-2015