20.
Connect supply water to Water In fitting on back of cabinet. Turn on water supply and flush RO
system to drain for 4 hours. Water should be draining from both Water Out line and the Drain
Line.
21.
After 4 hours of flushing, turn Off Incoming Water. Connect water line from the Base Cabinet to
Water In fitting on
WL400
.
22.
Open bladder tank and turn on supply water.
23.
Allow bladder tank to fill for 1 hour.
24.
Fill hot tank for approximately 1 minute. Depress both the “Hot” and “Extra Hot” buttons to
dispense. Red light should illuminate above the dispensing area after a 2 second delay.
25.
Fill cold tank for approximately 2 minutes. The Blue Light should
illuminate above dispensing area.
26.
Turn on Green Heater/Compressor Switch.
Fill the Hot Tank
27.
Press the Hot Water Select Button, followed by the main dispensing button to fill the hot tank.
Water will dispense from the faucet once the hot tank is full. Flush until water is clear.
WARNING!
HOT CIRCUIT IS NOT SANITIZED.
Water in the hot circuit is not sanitary until the temperature exceeds 171
o
F for at least 5 minutes.
UV System Functional Test
WARNING!
ULTRAVIOLET RADIATION.
Protect your skin and eyes against ultraviolet rays.
Never look directly at an operating UV light. Disconnect wiring before removing.
28.
Remove UV Firewall Lamp from Firewall housing. Remove top cover from Firewall housing.
Carefully remove quartz sleeve spiral from Firewall Housing and inspect for cracks or other
damage. Reinsert quartz sleeve spiral, replace top cover of housing. Inspect UV lamp and
reinsert into housing.
29.
Press dispensing button and check for blue glow from top of Firewall Housing and at Faucet
dispensing area to ensure UV lamp is operational.
30.
Disconnect UV lamp to test UV lamp sensor operation. Unit should alarm and UV Icon on display
will light.
31.
Disconnect power to
WL400
.
32.
Reconnect UV lamp.
33.
Connect power to
WL400
.
WL400
Operating, Installation, and Service Manual Page 29 - Revision: 5-29-2015
Содержание WL400 Series
Страница 15: ...BASE CABINET SIDE REMOVAL WL400 Operating Installation and Service Manual Page 15 Revision 5 29 2015...
Страница 16: ...BASE CABINET CONFIGURATION WL400 Operating Installation and Service Manual Page 16 Revision 5 29 2015...
Страница 19: ...RIGHT SIDE PANEL REMOVED WL400 Operating Installation and Service Manual Page 19 Revision 5 29 2015...
Страница 20: ...RO MEMBRANE INSTALLED WL400 Operating Installation and Service Manual Page 20 Revision 5 29 2015...
Страница 41: ...WL400 COUNTER TOP LAYOUT WL400 Operating Installation and Service Manual Page 41 Revision 5 29 2015...
Страница 42: ...WL400 BASE LAYOUT WL400 Operating Installation and Service Manual Page 42 Revision 5 29 2015...