5.
Allow descaling solution to remain in the Hot Tank for 15 minutes (length of time may vary
depending on water conditions).
6.
Place a pitcher, catch basin or other container under the faucet of the
WL400
.
7.
Flush the Hot Tank until water runs clear.
8.
Once clear Water dispenses from the faucet the Hot Tank has been descaled. Always ensure unit
is performing to the customer’s satisfaction.
WARNING!
HOT WATER HAZARD.
Unit Produces Very Hot Water and Steam. Always use
insulated and chemically compatible containers and let unit cool down before draining the hot
tank to avoid injury.
CAUTION
!
MUST
REPLACE HOT TANK 5 YEARS
. The hot tank and its controls must be
replaced a minimum of every five years to ensure efficient and dependable operation.
WARNING!
REINSTALL ALL PANELS AND COVERS.
Always reinstall all panels, protective
covers, and fasteners after servicing equipment. Failure to do so could result in severe personal
injury and will void the certifications and warranty of the equipment
.
WL400
Operating, Installation, and Service Manual Page 39 - Revision: 5-29-2015
Содержание WL400 Series
Страница 15: ...BASE CABINET SIDE REMOVAL WL400 Operating Installation and Service Manual Page 15 Revision 5 29 2015...
Страница 16: ...BASE CABINET CONFIGURATION WL400 Operating Installation and Service Manual Page 16 Revision 5 29 2015...
Страница 19: ...RIGHT SIDE PANEL REMOVED WL400 Operating Installation and Service Manual Page 19 Revision 5 29 2015...
Страница 20: ...RO MEMBRANE INSTALLED WL400 Operating Installation and Service Manual Page 20 Revision 5 29 2015...
Страница 41: ...WL400 COUNTER TOP LAYOUT WL400 Operating Installation and Service Manual Page 41 Revision 5 29 2015...
Страница 42: ...WL400 BASE LAYOUT WL400 Operating Installation and Service Manual Page 42 Revision 5 29 2015...